F. Shutdown

CAUTION

If there is a possibility that the ambient temperature may fall below 32°F (0°

C)and freeze the unit, be sure to drain the unit. The water supply line could be damaged and leak water, resulting in damage to the surrounding property.

To drain out the water heater, close the water supply line shut-off valve, and open the drain valve and water supply valve.

Water Heater

Dishwasher

Gas Supply Line

 

Shut-off Valve

 

Water Supply Line

 

Shut-off Valve

 

Water

 

Gas

 

Water Supply Valve

 

Drain Valve

 

1)Press the “ON/OFF” button on the operation panel. The display and lamps go off.

2)Open the cover in the front panel, then move the power switch (GFCI) to the “OFF” position.

3)Turn off the water heater.

4)Turn off the gas and water supplies.

IMPORTANT

To operate the water heater, follow its instruction manual.

5) Tilt back the rack rail.

IMPORTANT

The rack rail may fall down if tilted more than 10°. Do not hang anything from it or hit it hard.

6) Pull out the drain pipe to drain water from the wash tank.

WARNING

When pulling out the drain pipe, be careful not to touch the wash water. It may cause burns or skin irritation. Turn the drain pipe if it is hard to pull out.

68

Page 73
Image 73
Hoshizaki JWE-620UA-6B service manual Shutdown