3. Inadequate Rinse

Inadequate rinse

Problem

Low Rinse Pump

Output

Rinse Spray Arms

Dish Rack

Rinse (Internal Booster

Tank) Water

Rinse Cycle Time

Voltage

Possible Cause

Clogged with foreign matter.

Rinse water line scaled.

Voltage drop.

Rinse pump defective.

Obstructed by cutlery or other item.

Clogged

Out of position (not rotating evenly).

Low pump output.

Improperly loaded.

Temperature too low.

Too short.

Too low.

Remedy

Clean.

Clean.

Remove cause.

Replace.

Reposition the cutlery or other item.

Clean.

Set in position.

See “Low Rinse Pump Output.”

Load correctly.

Raise setting.

Adjust longer.

Call electrician.

43