DS8100A
3
3 AMETER DEFAULT VALUES
The following table contains the list of the factory default settings for the DS8100A.
Genius™ also allows checking the paramete fault values by selecting the "Compare
parameters" option available in the Tools menu and comparing the current scanner
configuration to the default one.
.4 PAR
r de
Parameter Default Setting
Code Definition
Code Combination Single Label
No read Message Global No Read Message
No Read String <CAN>
Multiple Read Filters abled (unchecked) Dis
Code Label Settings #1
Code Symbology Interleaved 2 of 5
Label Length 8
Min Code Position 0
Max Code Position 255
Check Digit Disabled (unchecked)
Decoding Safety 1
Decoding Severity 3
Pattern Match String Empty
Code Label Settings #2
Code Symbology Code 39
Label Length Variable
Minimum Label Length 1
Maximum Label Length 60
Min Code Position 0
Max Code Position 255
Check Digit isabled (unchecked) D
Decoding Safety 1
Decoding Severity 3
Pattern Match String mpty E
Operating Modes
Operating Mode Selection On Line
On Line Options On Line 1 Input
Start Input Number 1
Start Input Active Level Closed Active
Reading Phase Timeout abled (unchecked) Dis
Start Input from Bus Disabled (unchecked)
Verifier Disabled (unchecked)
Reading System Layout
Device Assignment Alone
Modify&Backup Lon Slave Configuration ) Disabled (unchecked
Enable A.S.R. (unchecked) Disabled
Reading Parameters
Beam Shutter isabled D
Overflow Start Ratio 5
50