INSTALLATION 3
MATRIX USER INTERFACE
Vext 30 Vdc max
+
-
I Load
V
Out
Figure 30 - Open Collector Output Connection
The electrical features of the output are the following:
OUTPUT ILoad VOut
Open 0 mA 30 Vdc Max
Closed 10 mA 1.8 Vdc Max
PD = VOut × IoLoad = 170 mW Max.