INSTALLATION 3

3.5 POSITIONING

Position the reader so that the distance from the reading window to the code surface is that
indicated in the figure below for your model.
115 mm
code surface
FOV
25 x 19 mm
1021 HD
(4.53 in)
(0.98 x 0.75 in)
focus distance
155 mm
code surface
(1.34 x 1.02 in)
FOV
34 x 26 mm
(6.10 in)
focus distance
1031 SD
1041 LD
110 mm
54 x 40 mm
(2.13 x 1.57 in)
FOV
code surface
(4.33 in)
focus distance
(3.74 x 2.75 in)
focus distance
(8.26 in)
210 mm
FOV
code surface
95 x 70 mm
1051 MR
Figure 32 – Positioning
Special models with different FOV and focus distance are available on request. Refer to your
local Datalogic distributor.
31