RAPID CONFIGURATION 1

1 RAPID CONFIGURATION

STEP 1 – CONNECTING THE SYSTEM

To connect the system in a Stand Alone configuration, you need the hardware indicated in
Figure 1. In this layout the data is transmitted to the Host on the RS232 auxiliary serial
interface which is also used for reader configuration by running VisiSet™.
When One Shot or Phase Mode Operating mode is used, the reader is activated by an
External Trigger (photoelectric sensor) when the object enters its reading zone.
CAB-600X
CBOX-100
Matrix-1000™
P.S.*
Local Host
Aux Interface
PG 6000
* External Trigger or Presence Sensor (for One Shot or Phase mode)
Figure 1 – Matrix-1000™ in Stand Alone Layout

C-BOX 100 Pinout for Matrix-1000™

The table below gives the pinout of the C-BOX 100 terminal block connectors. Use this
pinout when the Matrix-1000™ reader is connected by means of the C-BOX 100:
C-BOX 100 Terminal Block Connectors
Power Outputs
1, 3, 5 VS 21, 22 NC
2, 4, 6 GND 23, 24 NC
7, 8 EARTH GROUND 25 OUT 3+
20, 40 Reserved 26 OUT 3-
Inputs Auxiliary Interface RS232
27 EXT TRIG A (polarity insensitive) 35 TX AUX
28 EXT TRIG B (polarity insensitive) 37 RX AUX
29, 30 NC 38,39 GND
31, 33 NC Main Interface RS485 Half Duplex
32, 34 NC 11, 15 RTX 485+
36 NC 12, 16 RTX 485-
17 NC
18 NC
10, 14, 19 SGND
9, 13 RS485 Cable Shield
CAUTION
Do not connect GND and SGND to different (external) ground references.
GND and SGND are internally connected through filtering circuitry which
can be permanently damaged if subjected to voltage drops over 0.8 Vdc.
1