Problem

Possible Cause

What to do

Unclean dishes

Wash program unsuitable

Refer to the ‘Wash program chart’ for a

 

for the load.

suitable wash program, or the soils were

 

 

too heavily baked on and dishes may need

 

 

soaking.

 

Spray arm unable to rotate.

Ensure no items are obstructing the spray

 

 

arm path.

 

DishDrawer® overloaded/

Refer to the section on loading.

 

incorrectly loaded.

 

 

Filter plate/drain filter is

Refer to the ‘User maintenance instructions’

 

incorrectly inserted.

section.

 

Detergent put in the wrong

Detergent must be placed in the large

 

compartment.

compartment.

 

Excess food not removed

Scrape all food scraps off dinnerware prior to

 

from dinnerware prior to

loading.

 

loading.

 

 

Unsuitable detergent.

Use recommended brands of dishwasher

 

 

detergent.

 

Not enough detergent.

Refer to the detergent section or the

 

 

detergent manufacturer’s instructions.

 

Spray arm holes are blocked.

Clean the spray arm.

 

 

 

 

Filter plate/drain filter is

Clean the filter plate and drain filter.

 

blocked.

 

Foaming

Incorrect amount of

Refer to the detergent section or consult the

 

detergent.

detergent manufacturer’s instructions.

 

Too much egg in the wash

Increase the amount of detergent.

 

load.

 

 

Rinse agent setting too high.

Decrease the rinse agent setting.

Water leaking

Drain hose disconnected

Reconnect the drain hose to the waste pipe.

 

from waste pipe.

 

 

Water inlet hose not

Ensure the inlet hose is connected securely.

 

properly connected.

 

 

Other leaks.

Turn water and power supplies to the

 

 

DishDrawer® off. Call your dealer or

 

 

Authorized Service Agent.

DishDrawer® will Childlock feature is on or

not openthe Closed drawer option is on, or both.

Turn the Childlock off. Hold down the button until the light above it disappears and/or press the button to open the DishDrawer®.

Power failure

Wait until power resumes, cycle will restart in

during cycle.

same part of wash program.

 

 

Page 26
Image 26
DCS DD24 manual Troubleshooting

DD24 specifications

The DCS DD24 is an advanced dual fuel boiler designed for commercial and industrial applications, integrating cutting-edge technology with robust engineering to provide efficient heating solutions. This versatile boiler is renowned for its ability to operate on both natural gas and diesel, making it an ideal choice for facilities seeking flexibility in fuel sourcing and consumption.

One of the key features of the DCS DD24 is its high efficiency rating, which is achieved through innovative combustion technology that maximizes energy output while minimizing emissions. The boiler utilizes a sophisticated burner system that ensures a complete and clean burn of the fuel, resulting in lower operational costs and reduced environmental impact. With an efficiency rating that often exceeds 90%, the DD24 stands out among its competitors in the market.

The DD24 is equipped with advanced control systems that provide precise monitoring and modulation of the boiler’s operation. These systems enable real-time adjustments to fuel flow and combustion settings, optimizing performance based on current demand. The user-friendly interface allows operators to easily access critical data, monitor performance metrics, and troubleshoot issues, reducing downtime and enhancing operational reliability.

Another significant characteristic of the DCS DD24 is its compact design, which allows it to fit into tight spaces while still delivering high output. The modular construction of the boiler enables quick installation and easy maintenance, minimizing disruptions to facility operations. Its robust build quality ensures durability and longevity, making it a sound investment for various industrial sectors, including manufacturing, food processing, and chemical production.

In addition to its operational advantages, the DD24 is also designed with safety in mind. It features multiple safety controls and alarm systems that protect against overpressure, overheating, and fuel supply disruptions. These safety mechanisms ensure that the boiler operates within safe parameters at all times, providing peace of mind to operators and facility managers.

Overall, the DCS DD24 is a powerful and efficient dual fuel boiler offering a blend of innovative technology, safety features, and operational flexibility. Its ability to seamlessly switch between natural gas and diesel fuel, along with its high efficiency and compact design, make it a leading choice for businesses looking to optimize their heating processes while minimizing environmental impact.