User maintenance instructions

Cleaning the spray arm and filter plate

Ensure the DishDrawer® is cool before you start cleaning and follow the instructions for removing the drain filter and spray arm.

23US CA

1

Unplug the DishDrawer® or turn it off at the

 

 

 

1

 

power supply (wall switch)

 

2

 

2

Unclip the glass supports from the rack wires and

 

 

3

 

 

fold all the adjustable racks away, so that they are

 

 

 

 

upright and close to the top.

 

 

 

 

3

Remove the base rack carefully. Lift from the

 

 

 

 

 

back end first to prevent knocking the

 

2

 

 

 

detergent and rinse agent dispenser.

 

 

1

 

 

 

 

4

Lift the spray arm and shake any foreign material

 

3

4

 

out.

 

 

 

4

 

 

Rinse the spray arm clean under running water

 

5

 

 

and wipe the with a damp cloth.

 

 

6

 

5

In the center of the filter plate there are two rings.

 

 

 

 

 

Hold the center ring still and turn the outer ring

 

 

 

 

 

counter-clockwise, about a 1/8 turn. This will

 

 

 

 

 

release the filter plate.

 

a

 

 

6

Lift the filter plate out.

 

 

 

 

 

 

 

 

When cleaning the underside of the filter plate,

 

 

 

 

 

take care handling the sharp outer edge to avoid

 

 

 

 

 

the risk of cuts.

b

 

 

 

 

Remove any foreign material, wash in hot soapy

 

 

e

 

water and rinse thoroughly in clean water. The

 

 

 

 

 

heater plate can be wiped with a damp cloth.

c

 

 

 

7

Replace the filter plate so it lies flat in the base of

 

 

 

 

 

the drawer ensuring the filter plate is fully locked

 

 

 

 

 

into position with the center ring.

 

d

 

 

 

Important!

 

 

 

 

Correct locking position of

filter

 

To lock the filter plate into position, ensure the lines align

 

plate with motor assembly

 

 

with each other (c) and all three pin pairs firmly interlock (e).

 

 

(under spray arm)

 

 

 

Refer to the diagram for the correct position.

 

 

 

a

Outer ring

 

 

 

The filter plate must not be able to move about freely.

 

 

 

b

Impeller

 

 

8

Replace the spray arm back onto the impeller.

 

 

c

Correct alignment marks

9

Replace the base rack, lowering its front edge into

d

Center ring

 

 

 

position first.

 

 

 

e

Interlocking pins

 

10

Plug the DishDrawer® back in or turn it on at the

 

 

 

 

 

power supply (wall switch).

Note: Where there is broken crockery or glass in the drawer, it must be carefully removed to prevent damage to the DishDrawer®.

Page 25
Image 25
DCS DD24 manual Cleaning the spray arm and filter plate, Filter

DD24 specifications

The DCS DD24 is an advanced dual fuel boiler designed for commercial and industrial applications, integrating cutting-edge technology with robust engineering to provide efficient heating solutions. This versatile boiler is renowned for its ability to operate on both natural gas and diesel, making it an ideal choice for facilities seeking flexibility in fuel sourcing and consumption.

One of the key features of the DCS DD24 is its high efficiency rating, which is achieved through innovative combustion technology that maximizes energy output while minimizing emissions. The boiler utilizes a sophisticated burner system that ensures a complete and clean burn of the fuel, resulting in lower operational costs and reduced environmental impact. With an efficiency rating that often exceeds 90%, the DD24 stands out among its competitors in the market.

The DD24 is equipped with advanced control systems that provide precise monitoring and modulation of the boiler’s operation. These systems enable real-time adjustments to fuel flow and combustion settings, optimizing performance based on current demand. The user-friendly interface allows operators to easily access critical data, monitor performance metrics, and troubleshoot issues, reducing downtime and enhancing operational reliability.

Another significant characteristic of the DCS DD24 is its compact design, which allows it to fit into tight spaces while still delivering high output. The modular construction of the boiler enables quick installation and easy maintenance, minimizing disruptions to facility operations. Its robust build quality ensures durability and longevity, making it a sound investment for various industrial sectors, including manufacturing, food processing, and chemical production.

In addition to its operational advantages, the DD24 is also designed with safety in mind. It features multiple safety controls and alarm systems that protect against overpressure, overheating, and fuel supply disruptions. These safety mechanisms ensure that the boiler operates within safe parameters at all times, providing peace of mind to operators and facility managers.

Overall, the DCS DD24 is a powerful and efficient dual fuel boiler offering a blend of innovative technology, safety features, and operational flexibility. Its ability to seamlessly switch between natural gas and diesel fuel, along with its high efficiency and compact design, make it a leading choice for businesses looking to optimize their heating processes while minimizing environmental impact.