Cluster Storage Requirements

Hardware Components

Requirement

Storage system

One or more Dell EqualLogic PS Series groups. Each Dell EqualLogic PS5000/PS5500/

 

PS6000/PS6010/PS6100/PS6110/PS6500/PS6510 group supports up to sixteen storage

 

arrays (members) and each PS4000/PS4100/PS4110 group supports up to two storage

 

arrays. For specific storage array requirements, see Dell EqualLogic PS Series Storage

 

Array Requirements

Storage interconnect

All nodes must be attached to one or more storage arrays through an iSCSI SAN.

Multiple clusters and

Can share one or more supported storage arrays.

stand-alone systems

 

A Dell EqualLogic PS series storage array includes redundant, hot-swappable disks, fans, power supplies, and control modules. A failure in one of these components does not cause the array to be offline. The failed component can be replaced without bringing the storage array down.

The following section lists hardware requirements for the Dell EqualLogic PS series storage arrays.

Dell EqualLogic PS Series Storage Array Requirements

Dell EqualLogic Array Model

Minimum Required Features

PS4000 — PS4000E/PS4000X/PS4000XV

Redundant control modules

PS4100 — PS4100E/PS4100X/PS4100XV

 

PS4110 — PS4110E/PS4110X/PS4110XV

 

PS5000 — PS5000E/PS5000X/PS5000XV

 

PS5500 — PS5500E

 

PS6000 — PS6000E/PS6000X/PS6000XV/PS6000S

 

PS6010 — PS6010E/PS6010X/PS6010XV/PS6010S/PS6010XVS

 

PS6100 — PS6100E/PS6100X/PS6100XV/PS6100S/PS6100XS

 

PS6110 — PS6110E/PS6110X/PS6110XV/PS6110S/PS6110XS

 

PS6500 — PS6500E/PS6500X

 

PS6510 — PS6510E/PS6510X

 

NOTE: Ensure that the storage array(s) are running a supported firmware version. For specific firmware version requirements, see the Dell Cluster Configuration Support Matrices at dell.com/ha.

NICs Dedicated To iSCSI

The NIC controlled by the iSCSI software initiator acts as an I/O adapter to connect the expansion bus of the system and the storage array(s). Failover Cluster solutions that are configured with the EqualLogic PS Series storage arrays require two iSCSI NICs or NIC ports in each PowerEdge system. This provides redundant paths and load balance of the I/O data transfer to or from the storage array(s).

Network Switches Dedicated To iSCSI

The Gigabit or 10 Gigabit switches for iSCSI access function as regular network switches and provide dedicated interconnection between the nodes and the storage array(s).