Tr o u b l e s h o o t i n g
NOTE:
NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. (After the unit has been on its side, oil needs to return to the compressor to ensure proper function. With- out allowing the unit this time
TROUBLESHOOTINGi n g
PROBLEM | CAUSE | REMEDY |
The air conditio- ning unit does not start.
• No electricity. | • Restore electricity. |
• It is not plugged into the outlet. | • Plug into the outlet. |
• The safety device of the plug has tripped. | • Reset the safety plug. |
• The internal safety device has tripped. | • Wait 30 minutes, if the pro- |
| blem persists, contact your |
| service center. |
The air conditio-
ning unit works for • The air exhaust hose has a constriction. a short time only.
•The air exhaust hose is blocked.
•There are tight bends in the air exhaust hose.
•Position the exhaust hose correctly.
•Check there are no obsta- cles Obstructing air dischar- ge.
•Eliminate the tight bends.
The air conditioner | • | Window open. | • Close the window. | |
works, but does | • | There are heat sources in the room | • Eliminate the heat source. | |
not cool the room. |
| (lamps, etc.). |
| |
|
| • | The exhaust hose is detached. | • Connect the exhaust hose. |
|
| • | Air filters clogged. | • Clean or replace the filters. |
|
|
|
| |
Bad odor in the | • | The filter is clogged. | • Clean or replace the filter. | |
room. |
|
|
|
|
|
|
|
| |
The air conditioner | • | The internal compressor safety device | • Wait. This delay is part of nor- | |
does not operate |
| prevents the appliance from being restar- | mal operation. | |
for about 3 minu- |
| ted until three minutes have elapsed |
| |
tes after turning it |
| since it was last turned off. |
| |
on. |
|
|
|
|
|
|
|
|
|
/ PF/ | appears | • | The appliance has a self diagnosis system | • See the |
on the display. |
| to identify a number of malfunctions. | ter. | |
|
|
|
| |
The unit will not | • | The unit takes several minutes to produce | • Wait. This delay is part of | |
heat |
|
| warm air | normal operation. |