4.Remove the screw, flat washer and spacer (G) Fig. 30 that fasten the front inside leaf guard (H) to the front end of blade guard (J). Attach the blade guard
(J)to the motor assembly with a locking rod and washer (K).
5.
K
J
G
H
Fig. 30
The lower retractable blade guard provides protection in a LATERAL direction to the saw blade. Use the following guidelines to eliminate potential hazards with the lower blade guard.
A)Keep your hands away from the guard. As the blade cuts, the guard rises to leave a portion of the blade exposed.
B)Shut off the power before freeing a jammed lower guard. The guard can become jammed in previous kerfs in the table or fence. Always anticipate the path of the guard and the blade.
C)Use caution when bevel cutting to ensure that the lower guard is never pinched toward the blade.
D)The lower guard can jam against the fence during narrow
Make sure that the switch is in the “OFF” position before plugging cord into outlet. Do not touch the plug’s metal prongs when unplugging or plugging in the cord.
OPERATION
OPERATIONAL CONTROLS AND ADJUSTMENTS
CONNECTING THE SAW TO THE POWER SOURCE
To reduce the risk of injury, before connecting saw to power source, make sure the switch is in the "OFF" position.
Be sure your power supply agrees with the nameplate marking. AC Only means that your saw will operate on alternating current only. A voltage decrease of 10 percent or more will cause a loss of power and overheating. All DELTA tools are factory tested. If this tool does not operate, check the power supply.
STARTING AND STOPPING
Make sure that the switch is in the “OFF” position before plugging cord into outlet. Do not touch the plug’s metal prongs when unplugging or plugging in the cord.
The on/off switch (A) Fig. 31 is located at the front of the cuttinghead. To turn the saw “ON”, move the switch (A) up to the “ON” position. To turn the saw “OFF”, move the switch down to the “OFF” position.
LOCKING SWITCH IN THE "OFF" POSITION
IMPORTANT: When the machine is not in use, lock the switch in the “OFF” position to prevent unauthorized use by removing and storing the key (B) Fig. 31 in a safe place.
Fig. 31
B
A
In the event of a power outage (such as a breaker or fuse trip), always move the switch to the “OFF” position until the main power is restored.
15