BRUSH INSPECTION AND REPLACEMENT
BEFORE INSPECTING BRUSHES, DISCONNECT THE MACHINE FROM THE POWER SOURCE.
Brush life varies, depending on the load on the motor. Check the brushes after the first 50 hours, or after a new set of brushes has been installed.
After the first check, examine them about every 10 hours.
The brush holders (A) Fig. 54 are located on the motor housing opposite each other. Remove the brush holder cap (A) Fig. 55, and remove the brushes for inspection. When the carbon on either brush (B) is worn to 3/16" or less, or if either spring or shunt wire (C) is burned or damaged, replace both brushes. If the brushes are found serviceable after removing, reinstall them in the same position.
A
C A
B
Fig. 54 | Fig. 55 |
SERVICE
PARTS, SERVICE OR WARRANTY ASSISTANCE
All Delta Machines and accessories are manufactured to high quality standards and are serviced by a network of
ACCESSORIES
A complete line of accessories is available from your Delta Supplier,
for the name of your nearest supplier.
SINCE ACCESSORIES OTHER THAN THOSE OFFERED BY DELTA HAVE NOT BEEN TESTED WITH THIS PRODUCT, USE OF SUCH ACCESSORIES COULD BE HAZARDOUS. FOR SAFEST OPERATION, ONLY DELTA RECOMMENDED ACCESSORIES SHOULD BE USED WITH THIS PRODUCT.
21