Delta CP201, A05581 Troubleshooting, Problem, Cause, Correction, Do Not Overtighten. If

Models: CP201

1 56
Download 56 pages 39.86 Kb
Page 15
Image 15
TROUBLESHOOTING

TROUBLESHOOTING

Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or

compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure.

 

PROBLEM

CAUSE

CORRECTION

 

 

Thermal

Low voltage

Extension cord is wrong

 

overload

 

length or gauge. Check

 

protector cuts

 

extension cord.

 

out repeatedly

Improper ventilation/

Operate compressor in a

 

 

temperature too high

well ventilated area.

 

 

Defective check valve

Contact a Trained Service

 

 

 

Technician

 

 

Defective valves

Contact a Trained Service

 

 

 

Technician

 

 

 

 

 

Excessive tank

Compressor does not turn

Set Auto/On/Off switch to

 

pressure - safety

off when compressor

the "OFF" position, if the

 

valve pops off.

reaches "cut-out" pressure.

unit does not shut off contact

 

 

 

a Trained Service Technician.

 

 

 

Contact a Trained Service

 

 

Pressure switch "cut-out"

Technician.

 

 

too high.

 

 

 

 

 

 

 

 

 

 

 

 

 

Air leaks at

Tube fittings are not tight

Using a soapy water solution

 

check all exposed fittings for

 

fittings.

enough.

 

leaks. If needed reseal

 

 

 

 

 

 

fittings with pipe sealant

 

 

 

tape and retighten securely.

 

 

 

Do Not Overtighten. If

 

 

 

leaks continue contact a

 

 

 

Trained Service Technician.

 

 

 

 

 

 

 

 

 

 

Air leaks in air

Defective air tank.

Air tank must be replaced.

tank or at air

 

Do not repair the leak.

tank welds.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not drill into, weld or

 

 

 

otherwise modify air tank

 

 

 

or it will weaken. The tank

 

 

 

can rupture or explode.

 

 

 

 

 

 

 

 

 

 

15- ENG