STARTING

STARTING

Prior to starting, refer to your engine manual for proper starting procedures for your engine type.

1.In a well ventilated outdoor area add fresh, high quality, unleaded gasoline with a pump octane rating of 86 or higher. Do not overfill. Wipe up spilled fuel before starting the engine. Refer to Engine Owners Manual for correct procedure.

2.Check engine oil level. See Engine Owners Manual for correct procedure.

NOTE: There will be a slight amount of oil in the engine from factory testing.

3. Verify the filter screen is in water inlet of pump.

Filter Screen

NOTE: Cone side faces out.

 

4.Connect water source to pump inlet.

NOTE: Water source must provide a minimum of 5 gallons per minute at 20 p.s.i.

5.Connect high pressure hose to pump outlet.

6.If applying a chemical or cleaning solution, see

How To Apply Chemicals/Cleaning Solvents in

 

High Pressure Hose

Operation section of this manual.

 

 

7.

Turn water source on. NOTE: Failure to do so could

 

 

 

cause damage to the pump.

 

 

8.

Start engine. See Engine Owners Manual for correct

 

 

 

procedure. NOTE: If the engine does not start after

 

 

 

two pulls, pull the trigger to relieve the pressure.

 

 

 

Water

 

9.

Depress trigger on gun to start water flow. NOTE:

 

Source

 

 

Stand on a stable surface and grip gun/spray wand

 

 

 

 

 

 

 

firmly with both hands. Expect the gun to kick when triggered.

 

 

10.Release trigger to stop water flow.

11.Adjust spray for the task being performed by changing quick connect nozzle. See How To Use Spray Wand instructions in this section.

SHUTTING DOWN

1.After each use, if you have applied chemicals, place chemical hose into container of clean water and draw clean water through chemical injection system to rinse system thoroughly. NOTE: Failure to do so could cause damage to the pump.

2.Turn engine off. See Engine Owner’s Manual. NOTE: NEVER turn the water off with the engine running.

3.Turn water source off.

4.Pull trigger on spray gun to relieve any water pressure in hose or spray gun.

5.See Storage section in this manual for proper storage procedures.