SECTION I - Pre-Installation Items

Code Compliance

This product must be installed in accor- dance to the following:

All applicable local, state, national and provincial codes, ordinances, regula- tions and laws.

The National Fuel Gas Code NFPA54/ ANSI Z332.1 - Latest edition.

Installation of Oil Burning Equipment NFPA 31 - Latest Edition

National Electric Code ANSI/NFPA 70.

For installations in Canada -“Installation Code for Gas Burning Equipment” CGA/B149.

For installations in Canada - Installation code for Oil Burning Equipment - CSA/B139.

Determining Product Location

Before locating the ELITE check for conve- nient locations to:

-Domestic water supply piping

-Heating system piping

-Venting

-Gas or oil supply piping

-Electrical service

Ensure the area chosen for the installation of the ELITE is free of any combustible materials, gasoline and other flammable liquids.

WARNING

Failure to remove or maintain the area free of combustible materials, gasoline and other flammable liquids or vapors can result in severe personal injury, death or substantial property damage.

Ensure the ELITE and its controls are protect- ed from dripping or spraying water during nor- mal operation or service.

The ELITE should be installed in a location so that any water leaking from the tank or piping connections or relief valves will not cause damage to the area surrounding the unit or any lower floors in the structure.

-When such a location is unavoidable a suitable drain pan with adequate drainage should be placed under the unit. The drain pan must not restrict the flow of combustion air to the unit.

Boiler Replacement

If the ELITE is replacing an existing boiler / hot water heater system, the following items should be checked and corrected prior to instal- lation:

Primary and domestic piping leaks and corrosion.

Improper location and sizing of the expansion tank on the primary heating loop.

Improper sizing of the thermal expan- sion tank (if used) on the domestic sup- ply line.

Vent condition and sizing.

Recommended Clearances

The ELITE is approved for zero clearance to combustibles, excluding the vent hood and vent piping.

Vent hood and vent piping - 6 inches from combustible materials when using type “L” double wall vent.

Vent Piping - 18 inches from combustible materials when using single wall vent.

Primary and domestic hot water piping - 1 inch from combustible material.

5