Delta 40, F-25, 35, 30, 45 warranty External Wiring, Wire Zone Valve

Models: 45 30 35 40 F-25

1 57
Download 57 pages 26.34 Kb
Page 39
Image 39
4 Wire Zone Valve

External Wiring

4 Wire Zone Valve

V.A.C. High Voltage

Transformer

 

(Power)

 

 

24

 

V.A.C.

Room

Zone Valve

Thermostat

Zone 1

 

Room

 

Thermostat

 

Zone 2

 

 

Zone

 

Valve

Additional zones 3 Wire Zone Valve

Additional zones may

be added as shown above

C 1

To ELITE

"Room Thermostat"

Snap Set

3 Wire Zone Valve

H

120

H

 

Transformer

V.A.C.

High Voltage

 

 

 

 

(Power)

 

 

 

 

24

 

 

 

V.A.C.

 

 

Room

Zone Valve

 

Thermostat

Zone 1

Room

Thermostat

Zone 2

Zone

Valve

*Use isolation relay on 3-wire zone valve with non-isolated end switch. Transformer and the ELITE control can burn out if isolation relay is not used.

Additional zones Manual background

Additional zones may

be added as shown above

* Isolation relay

1

To ELITE

C

"Room Thermostat"

Snap Set

 

Fig. 18: Multiple Zone Field Wiring Using Zone Valves

34

Page 39
Image 39
Delta 40, F-25, 35, 30, 45 warranty External Wiring, Wire Zone Valve