SECTION VIII - Internal Wiring

WARNING

ELECTRICAL SHOCK HAZARD. For your safety, disconnect electrical power supply to the unit before servicing or making any electrical connections to avoid possible electric shock hazard. Failure to do so can cause severe person- al injury or death.

NOTICE

General Requirements

-Wiring must be N.E.C Class 1.

-If original wiring as supplied with the unit must be replaced, use only type 90ºC wire or equivalent.

-The ELITE must be electrically grounded as required by National Electrical Code ANSI/NFPA 70 - latest edition.

All electrical contacts shown in Figures 15 & 16 pages 31 & 32 do not have elec- trical power applied. Shown as “off- shelf” condition.

 

 

H

 

120 VAC

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

On-Off

 

 

 

 

 

 

 

 

Wire Color Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch

 

 

 

 

 

Equipment

 

 

 

 

 

 

 

 

 

 

 

 

 

Ground

 

 

 

 

 

 

 

Manual

 

 

 

 

 

2

 

 

 

 

 

 

 

 

Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limit

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R2A

 

 

B

Circulator

 

 

 

 

 

 

 

 

 

 

B

B

3

 

 

 

 

 

 

 

 

 

 

R1A

 

 

Burner Control

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

r

r

B

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120V

 

 

 

 

 

 

 

 

 

5

 

Y

 

 

 

 

BL

 

 

 

 

 

 

6

 

 

 

24V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

Room T-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

Snap-Set

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

LWCO

Factory

 

 

 

 

 

B

B

 

 

 

 

 

 

Jumper

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OR

 

12

13

T

 

 

T

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

 

 

 

 

 

 

R2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Secondary

 

 

 

 

 

 

 

 

 

 

 

 

 

T-Stat

 

 

 

 

 

 

 

V

 

 

 

 

 

Y

 

 

BL BL

11

P

P

14

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto

 

R1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

BL

BL

 

Reset

 

 

 

 

 

 

 

 

 

10

 

Limit

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R2B

 

 

 

 

 

 

 

 

 

 

 

Primary

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory

 

 

 

 

 

 

 

 

 

 

 

 

 

Jumper

 

 

 

 

 

 

Fig. 15: ELITE Factory Internal Wiring

 

 

 

 

 

 

 

 

 

 

 

 

 

 