ENGLISH

 

Select the memory using the 2 cursor buttons (0,

 

 

 

 

 

 

 

1) and press the ENTER button.

 

 

 

 

 

 

 

 

IMAGE QUALITY ADJUSTMENT 1

 

MEMORY 1

1

 

2

3

 

 

This

permits adjustment of the

contrast,

0

0

M

H

0

0

 

brightness, sharpness, tint, and enhancer. /

0

0

 

 

 

 

 

 

 

 

Advance to Operation 3.

 

Remote control unit

 

 

 

 

 

 

IMAGE QUALITY ADJUSTMENT 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This permits adjustment of the setup level, black

ENTER

 

 

 

 

 

 

level, white level, color density, chroma delay, and

 

 

 

 

 

 

2

fresh color. / Advance to Operation 4.

 

 

 

 

 

 

 

NOISE REDUCTION (ADJUSTMENT 3)

Remote control unit

 

 

 

 

 

 

The following types of noise reduction can be

 

 

 

 

 

 

adjusted: 3D NR (3D noise reduction), BLNR

 

 

 

 

 

 

 

(block noise reduction), MQNR (mosquito noise

 

 

 

 

 

 

 

reduction), and CCS (cross color suppression). /

 

 

 

 

 

 

 

Advance to Operation 5.

 

 

 

 

 

 

 

 

GAMMA CORRECTION

 

 

 

 

 

 

 

 

This is selected when dark portions of the image

 

 

 

 

 

 

 

are obscure, or bright portions are much brighter

 

 

 

 

 

 

 

than necessary. / Advance to Operation 6.

 

 

 

 

 

 

 

When Image Quality Adjustment 1 Is Selected and

 

 

 

 

 

 

 

Adjusted:

 

 

 

 

 

 

 

 

• Press

cursor button (ª), then select

the image

MEMORY 1

1

 

2

3

 

 

quality adjustment item with cursor buttons (0,

 

 

M

H

 

 

 

0

0

0

0

0

0

 

1), set the adjustment value with cursor buttons

 

 

 

 

 

 

 

 

(, ª), and press the ENTER button.

 

 

 

 

 

 

 

 

• All of the adjusted contents will be stored.

Remote control unit

 

 

 

 

 

 

CONTRAST (–6 to +6) (Factory default: 0)

 

 

 

 

 

 

 

 

 

 

 

 

 

• This adjusts the light/dark difference of the image.

ENTER

 

 

 

 

 

 

 

 

 

 

 

 

 

BRIGHTNESS (0 to +12) (Factory default: 0)

 

 

 

 

 

 

 

• This adjusts the brightness of the image.

 

 

 

 

 

 

3

SHARPNESS (MID) (–6 to +6) (Factory default: 0)

Remote control unit

 

 

 

 

 

• This adjusts the sharpness of the image for the

 

 

 

 

 

 

 

 

 

 

 

 

intermediate frequencies.

 

 

 

 

 

 

 

 

SHARPNESS (High) (–6 to +6) (Factory default: 0)

 

 

 

 

 

 

 

• This adjusts the sharpness of the image for the

 

 

 

 

 

 

 

high frequencies. (Only effective for progressive

 

 

 

 

 

 

 

images.)

 

 

 

 

 

 

 

 

HUE (–6 to +6) (Factory default: 0)

 

 

 

 

 

 

 

 

• This adjusts the balance between green and red.

 

 

 

 

 

 

 

(Not effective for progressive scan output nor

 

 

 

 

 

 

 

component output.)

 

 

 

 

 

 

 

 

ENHANCER (0 to +7) (Factory default: 0)

 

 

 

 

 

 

 

This emphasizes the contour of the image.

 

 

 

 

 

 

When Image Quality Adjustment 2 Is Selected and

Adjusted:

BLACK LEVEL (–5 to +5) (Factory default: 0)

MEMORY 1

 

1

2

3

• This adjusts the black level.

0

-2

-6

 

-6

 

 

WHITE LEVEL (–5 to +5) (Factory default: 0)

4

• This adjusts the white level.

Remote control unit

CHROMA LEVEL (–6 to +6) (Factory default: 0)

 

 

• This adjusts the density of the color.

ENTER

 

 

 

CHROMA DELAY (–2 to +2) (Factory default: 0)

 

 

• This adjusts the shift of the brightness signal and

 

 

the color signal of the image. (Only effective for

 

 

progressive images.)

Remote control unit

49