Drain Pump Kit (Optional) (Office Pro 12 model ONLY)

OPERATION (cont.)

Drain Pump Kit (Optional) (Office Pro 12 model ONLY)

A drain pump kit (CPK-3) is available to allow continuous operation and to eliminate the need for a drain tank.

When the water collects to level

(A) in the pump reservoir, the drain pump begins to operate and discharges the water.

A

B

NOTE: The compressor will not

operate while the drain pump is discharging water.

When the water level drops below level (B), the drain pump stops, and the compressor will restart.

NOTE: If for any reason the water level exceeds that of level (A) in the pump reservoir, an overflow Drain Switch will stop the compres- sor operation.

NOTE: If the Fan Mode Control DIP Switch (see pg. 13) is set to the STOP position, the entire unit (including fan operation) will turn off whether due to the overflow Drain Switch or while the drain pump is discharging water.