OPERATING FIREPLACE
Lighting Instructions
To Turn Off Gas To Appliance
Manual Lighting Procedure
17
OPERATING FIREPLACE
Continued
LIGHTING
INSTRUCTIONS
NOTICE: During initial operation of new heater, burn- ing logs will give off a
1.STOP! Read the safety information on page 16, column 2.
2.Make sure equipment shutoff valve is fully open.
3.Set switch in OFF position.
WARNING: Burner will come on automatically within one minute when the selector switch is in the ON position after the pilot is lit.
4.Press in and turn control knob clockwise to the OFF position.
5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information on page 16, column 2. If you don’t smell gas, go to the next step.
6.Press in and turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 32).
Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.
7.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.
8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
•If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8.
Selector Switch | Flame Adjustment Knob | |
AUTO | IH |
|
| O | |
OFF |
| |
| F | |
ON | N | F |
O | P | |
| LO | LI |
| TO | |
Ignitor Button | Control Knob |
Figure 32 - Control Knob and Ignitor Button Location (Shown as Supplied, No Control Options)
9.Slightly push in and turn control knob counterclockwise to the ON position.
10.Wait one minute and switch selector switch to the ON posi- tion to light burner.
11.Set flame adjustment knob to any level between HI and LO.
CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.
WARNING: Make sure the selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on automatically with selector switch in the ON position.
Pilot Burner | Ignitor |
| Electrode |
Figure 33 - Pilot
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1.Turn control knob clockwise to the OFF position.
2a. Set selector switch in the OFF position
2b. If Using Optional
Shutting Off Burner Only (pilot stays lit)
You may shut off the burner and keep the pilot lit by doing one of the following:
1.Turn control knob clockwise to the PILOT position.
2.Use remote control manual OFF button.
3.Set selector switch in the OFF position.
MANUAL LIGHTING
PROCEDURE
1.Follow steps 1 through 6 under Lighting Instructions.
2.Depress control knob and light pilot with match.
3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11 under Lighting Instructions.
For morevisit www..com