Desa CF26NR installation manual Mantel Clearances for BUILT-IN Installation, Assembling Brass Trim

Models: CF26NR

1 32
Download 32 pages 21.74 Kb
Page 9
Image 9

INSTALLATION

Mantel Clearances For Built-In Installation

Removing Brick Liner Retainer

Assembling Brass Trim

Optional Mantel Installation

9

INSTALLATION

Continued

MANTEL CLEARANCES FOR BUILT-IN INSTALLATION

NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual.

If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.

NOTICE: If your installation does not meet the mini- mum clearances shown, you must do one of the following:

raise the mantel to an acceptable height

remove the mantel

Mantel Shelf

10"

ASSEMBLING BRASS TRIM

(Brass trim shipped with mantel)

1.Remove packaging from three pieces of brass trim.

2.Locate two adjusting plates with set screws, and two shims in the hardware packet.

3.Align shim under adjusting plate as shown in Figure 9.

4.Slide one end of adjusting plate/shim in slot on mitered edge of top brass trim (see Figure 9).

5.Slide other end of adjusting plate/shim in slot on mitered edge of side brass trim (see Figure 9).

6.While firmly holding edges of brass trim together, tighten both set screws on the adjusting plate with slotted screwdriver.

7.Repeat steps 1 through 6 for other corner.

8.Set brass assembly aside for later installation.

Slot

 

 

Set Screws

 

 

 

 

Top

 

Mitered

Brass

Shim

Trim

 

Note: All vertical measurements are from top of fireplace opening to bottom of mantel shelf.

Minimum Non-

Combustible

Material

8"

6"

2 1/2"

13"

16"

19"

21"

Adjusting

 

Edge

 

Side

Plate

 

Brass

 

Slot

Trim

 

 

Figure 9 - Assembling Brass Trim

OPTIONAL MANTEL INSTALLATION

Note: Refer to instructions provided with the mantel for assembly instructions. Refer to instructions below for system installation. If using blower accessory (see Accessories, page 31), see installation instructions on pages 10 and 11.

Figure 8 - Minimum Mantel Clearances for Built-In Installation

1.Choose location for fireplace and install gas supply line.

2.Remove screen from fireplace by removing screws in each end of screen rod (see Figure 10). Hold screen rod cover while removing five hex head screws underneath hood (see Figure 11, page 10). Carefully lift and pull out hood (see Figure 12, page 10).

REMOVING BRICK LINER RETAINER

1. Using Phillips screw driver, remove 2 screws attaching brick liner retainers to vertical sides.

2. Remove brick liner retainers and discard. Replace 2 screws into vertical sides.

Figure 10 - Removing Screen

For morevisit www..com