20
CLEANING AND MAINTENANCE
Cleaning Burner Injector Holder And Pilot Air Inlet Hole (Cont.) Cabinet
SPECIFICATIONS
WIRING DIAGRAM
CLEANING AND
MAINTENANCE
Continued
2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 40).
3.Blow air through the ports/slots and holes in the burner.
4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.
5.Blow air into the primary air holes on the injector holder.
6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.
Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 41). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.
Injector Holder (May Be Brass or
Aluminum Depending on
Model)
Burner
Tube
Primary Air Inlet Holes (Shape of Holes May Vary by Model)
Figure 40 - Injector Holder On Outlet Burner Tube
CABINET
Air Passageways
• Use a vacuum cleaner or pressurized air to clean.
Exterior
•Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.
SPECIFICATIONS
Btu (Variable) | 19,000/26,000 |
Type Gas | Natural Only |
Ignition | Piezo |
Manifold Pressure | 3.5" W.C. |
Inlet Gas Pressure (in. of water) * | |
Maximum | 10.5" |
Minimum | 5" |
Dimensions, Inches (H x W x D) | |
Fireplace | 25 7/8 x 27 x 13 3/4 |
Carton | 28 x 26 13/16 x 16 1/2 |
Weight, pounds |
|
Fireplace | 44 1/2 lbs. |
Shipping | 55 lbs. |
* For purposes of input adjustment
WIRING DIAGRAM
Ports/Slots
Burner
Tube
Pilot
Assembly
Pilot Air
Inlet Hole
Figure 41 - Pilot Inlet Air Hole
Auto |
|
Off | Switch |
On |
|
Thermopile
Black
Red
TPTH TP TH
Gas Control
TPTH TP TH
Red
White
For..com