OPERATING FIREPLACE

Continued

D.Do not use this appliance if any part has been under water. Immediately call a quali- fied service technician to inspect the appli- ance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

WARNING: You must oper- ate this fireplace with the screen in place. Make sure fireplace screen is installed before run- ning fireplace.

NOTICE: During initial operation of new fireplace, burning logs will give off a paper-burning smell. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.

1.STOP! Read the safety information above.

2.Make sure equipment shutoff valve is fully open.

3. Turn control knob clockwise Clockwise to the

OFF position.

4.

Wait five (5) minutes to clear out any gas.

 

Then smell for gas, including near the floor.

 

If you smell gas, STOP! Follow “B” in the

 

safety information above. If you don’t smell

 

gas, go to the next step.

5.

Turn control knob counterclockwise C-clockwise

 

to the PILOT position. Press in control knob

 

for five (5) seconds (see Figure 36).

 

Note: You may be running this fireplace

Note: If pilot does not stay lit, refer to Troubleshooting, page 31. Also, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure on page 25.

7.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This fireplace has a safety inter- lock system. Wait one (1) minute for sys- tem to reset before lighting pilot again.

8.Turn control knob counterclockwise

C-clockwiseto desired heating level. The burner should light. Set control knob to any heat level between 5 (high) and 1 (low).

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Electronic

Ignitor Button

Control Knob

Figure 36 - Control Knob In The OFF

Position

Thermocouple

Ignitor Electrode

 

Pilot Burner

Figure 37 - Natural Gas Pilot

for the first time after hooking up to gas

supply. If so, the control knob may need to

Ignitor

Thermocouple

be pressed in for 30 seconds or more. This

will allow air to bleed from the gas system.

• If control knob does not pop out when

released, contact a qualified service per-

son or gas supplier for repairs.

6. With control knob pressed in, press and

release ignitor button (see Figure 36). This

will light pilot. The pilot is attached to the

front burner. If needed, keep pressing igni-

tor button until pilot lights.

ElectrodePilot Burner

Figure 38 - Propane/LP Gas Pilot

24