AIR FOR COMBUSTION

AND VENTILATION

Continued

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-con- trolled power vent. Heated air entering the attic will activate the power vent.

 

12"

 

Ventilation Grills

Ventilation

Into Adjoining Room,

Option 2

Grills

Or

into Adjoining

Remove

Room,

Door into

Option 1

Adjoining

 

Room,

 

Option 3

 

12"

Figure 4 - Ventilation Air from Inside

Building

 

Outlet

Ventilated

 

Attic

 

Air

 

 

Outlet

 

 

Air

 

To Attic

 

 

 

 

To

 

 

Crawl

Inlet

 

Space

 

 

Air

 

 

 

Inlet Air

Ventilated

 

Crawl Space

 

 

Figure 5 - Ventilation Air from Outdoors

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your pri- mary heat source.

WARNING: A qualified ser- vice person must install fire- place. Follow all local codes.

WARNING: Never install the fireplace

in a bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the fireplace

as a fireplace insert

in high traffic areas

in windy or drafty areas

CAUTION: This fireplace cre- ates warm air currents. These currents move heat to wall sur- faces next to fireplace. Install- ingfireplacenexttovinylorcloth wall coverings or operating fire- placewhere impurities (suchas, but not limited to, tobacco smoke,aromaticcandles,clean- ing fluids, oil orkerosenelamps, etc.) in the air exist, may dis- color walls or cause odors.

112462-01C

www.desatech.com

9

Page 9
Image 9