Desa CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT

Models: CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT

1 42
Download 42 pages 1.89 Kb
Page 18
Image 18
OPERATING

VENT-FREE NATURAL GAS LOG HEATER

OPERATING

HEATER

Manually-Controlled Models

FOR YOUR SAFETY

READ BEFORE

LIGHTING

Manually-Controlled Models WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un- der water.

LIGHTING

INSTRUCTIONS

LIGHTING WARNING:

If fireplace has glass doors, never operate this heater with glass doors closed. If you oper- ate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell.Thiswillonlylastafewhours.

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the Hi heat setting but will find the heat output excessive. You can open the chim- ney damper (if you have one) fully or partially to release some of the heat.

Manual background WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information, column 1.

2.Make sure equipment shutoff valve is fully open.

3.Press in and turn control knob clock- wise ClockwiseManual background to the OFF position.

HI Manual backgroundPILOT

Manual background OFF

LOManual background

Ignitor Button Control Knob

Figure 38 - Control Knob and Ignitor Button Location

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation above. If you don’t smell gas, go to the next step.

5.Slightly depress and turn control knob

counterclockwise Manual backgroundC-clockwiseto the PI-

LOT position. Press in control knob for five (5) seconds (see Figure 38).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the burner. If needed, keep pressing ig- nitor button until pilot lights.

Note: If pilot does not stay lit, con- tact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Light- ing Procedure, page 19.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. If control knob does not pop out when released, contact a qualified service person or gas sup- plier for repairs.

8.Slightly depress and turn control

knob counterclockwise Manual backgroundC-clockwiseto desired heating level. The burner(s) should light. Set control knob to any heat level between HI and LO.

Manual background WARNING: Do not operate heater between PILOT and HIGH positions.

Ignitor Electrode

Thermocouple

Pilot Burner

Figure 39 - Pilot

For more information, visit www.desatech.com

18

107123

Page 18
Image 18
Desa CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT Operating Heater