INSTALLATION

OWNER’S MANUAL

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

CHECK GAS TYPE WARNING: A qualified ser- vice person must install heater. Follow all local codes.

NOTICE: State or local codes may only allow operation of this appli- ance in a vented configuration. Check your state or local codes.

INSTALLATION AND WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes, and loose paint by a quali- fied chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and dis- tribute soot within the house. In- spect chimney flue for damage. If damaged, operate heater with flue damper closed.

Manual background WARNING: Seal any fresh air vents or ash clean-out doors lo- cated on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat- resistant sealant. Do not seal chimney flue damper.

Manual background WARNING: Never install the heater

in a bedroom or bathroom un- less installed as a vented ap- pliance (Variable Manually- Controlled Models Only) (see page 10)

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

Manual background CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as to- bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc) in the air exist, may discolor walls.

IMPORTANT: Vent-free heaters add mois- ture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Com- bustion and Ventilation, pages 4 through 6.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION AND

CLEARANCES (Vent-Free

Operation Only)

Manual background WARNING: Maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall.

MINIMUM FIREPLACE CLEARANCE

TO COMBUSTIBLE MATERIALS

Log Size

 

Side Wall

Ceiling

18", 24", 30"

16"

 

 

42"

 

 

 

 

 

 

 

 

 

 

 

 

LOG SIZING REQUIREMENTS

 

 

 

 

 

 

Minimum Firebox Size

Log

 

 

 

Front

Rear*

Size

Height

 

Depth

Width

Width

18"

17"

 

14"

24"

 

20"

24"

17"

 

14"

28"

 

21"

30"

17"

 

14"

34"

 

24"

 

 

 

 

 

 

 

*Measured at 14" Depth

Carefully follow the instructions below. This will ensure safe installation into a masonry, UL127-listed manufactured fireplace, or cer- tified vent-free firebox.

Continued