Desa CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT

Models: CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT

1 42
Download 42 pages 1.89 Kb
Page 19
Image 19
VARIABLE CONTROL

OWNER’S MANUAL

OPERATING

HEATER

Continued

VARIABLE CONTROL

OPERATION

The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides realistic, dancing yellow flames. Selecting higher settings produces greater heat output. This results in in- creased heating comfort.

TO TURN OFF GAS CAUTION: Do not try to adjust heating levels by using the manual shutoff valve.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Press in and turn control knob clock-

wise ClockwiseMANUAL LIGHTING to the HIGH position.

2. Turn control knob clockwise ClockwiseThermostatically-Controlled Models to the pilot position.

3.Press in control knob and turn clock-

wise ClockwiseLIGHTING to the OFF position.

Shutting Off Burner(s) Only (pilot stays lit)

1. Turn control knob clockwise ClockwiseManual background to the HIGH position.

2.Press in and turn control knob clock-

wise ClockwiseManual background to the pilot position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Light- ing Instructions, page 18.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 on page 18.

Thermostatically-Controlled Models

FOR YOUR SAFETY

READ BEFORE

LIGHTING

Manual background WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un- der water.

LIGHTING

INSTRUCTIONS

Manual background WARNING

If fireplace has glass doors, never operate this heater with glass doors closed. If you op- erate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the Hi heat setting but will find the heat output excessive. You can open the chim- ney damper (if you have one) fully or partially to release some of the heat.

Manual background WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information, column 2.

2.Make sure equipment shutoff valve is fully open.

3. Turn control knob clockwise ClockwiseManual background to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation above. If you don’t smell gas, go to the next step.

Continued

107123

19

For more information, visit www.desatech.com

Page 19
Image 19
Desa CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT Variable Control Operation