Image 20
INSTALLING SCREEN

UNVENTED NATURAL GAS FIREPLACE

INSTALLATION

Continued

INSTALLING SCREEN

INSTALLING BATTERY INTO REMOTE WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fire- place screen is in place before running fireplace.

Install fireplace screen by slipping notches of fireplace screen over screws on front of fireplace (see Figure 47).

Notches

Screws for Mounting Screen

Figure 47 - Installing Fireplace Screen

INSTALLING BATTERY INTO REMOTE

1.Locate slot at bottom of remote control (see Figure 48). Firmly insert tool such as a small screwdriver, butter knife, or dime into the slot and lift up to remove cover.

2.Insert supplied battery into remote control. Positive and negative are marked inside remote control casing. Note: Remote will not function if bat- tery is not installed correctly.

3.Slide tab on cover into remote housing and snap cover back into place.

Tab

OPERATING

FIREPLACE

FOR YOUR SAFETY

READ BEFORE

LIGHTING

OPERATING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.

This appliance has a pilot which lights

 

automatically when using the sup-

 

plied wall switch or remote control.

 

If you have a power outage, the pilot

 

may be lighted by hand with push-

 

button piezo ignitor. When lighting

 

the pilot, the following warnings

 

must be followed.

B. BEFORE LIGHTING smell all

 

around the appliance area for gas. Be

 

sure to smell next to the floor because

 

some gas is heavier than air and will

 

settle on the floor.

 

WHAT TO DO IF YOU SMELL

 

GAS

 

Do not try to light any appliance.

 

Do not touch any electric switch;

 

 

do not use any phone in your building.

 

• Immediately call your gas supplier

 

 

from a neighbor’s phone. Follow

 

 

the gas supplier’s instructions.

 

If you cannot reach your gas sup-

 

 

plier, call the fire department.

C. Electric Power Outage Only: Use only

 

your hand to turn the manual over-

 

ride handle on the gas control knob.

 

Never use tools. If the knob will not

 

turn by hand, don’t try to repair it,

 

call a qualified service technician or

 

gas supplier. Force or attempted re-

NORMAL LIGHTING

INSTRUCTIONS

FOR YOUR SAFETY WARNING: You must operate this heater with the fireplace screen in place. Make sure fire- place screen is in place before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Open damper or window to vent smell. This will only last a few hours.

1.STOP! Read the safety information, in column 1.

2.Make sure equipment shutoff valve is fully open.

3.Wait five (5) minutes to clear out any gas. Smell for gas around heater and near floor. If you smell gas, STOP! Follow “B” in the safety information on warnings plate. If you don’t smell gas, go to the next step.

A. Using Supplied Wall Switch

1. Set manual ignition bypass switch on

the control panel to the OFF position

(automatic ignition position).

2. Press ON/OFF button. Hold for 6

seconds. Gas valve will open and elec-

tronic ignition will begin sparking to

light pilot. LED will light.

Note: You may be running this

heater for the first time after connect-

ing to gas supply or at the start of

your heating season. If so, the ON/

OFF button may need to be pressed

again. This will allow air to bleed

from gas system. If several attempts

to light pilot fail, contact a qualified

Slot

Cover

pair may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately

call a qualified service technician to

inspect the appliance and to replace

any part of the control system and

any gas control which has been un-

service person or gas supplier for re-

pairs. Until repairs are made, light

and operate manually (see Manual

Lighting Instructions for Electric

Power Outage, page 21).

3. When pilot flame is lit, the thermo-

couple is heated by the flame. When

thermocouple becomes hot (5 to 15

Remote

PositiveControl

Negative

Figure 48 - Installing Battery

der water.

seconds), main burner will automati-

cally light on high flame.

For more information, visit www.desatech.com

20

107569

Page 20
Image 20
Desa CGEFP33NR Operating Fireplace, Installing Screen, Installing Battery Into Remote, Normal Lighting Instructions