 CAUTION: Do not apply ex- cessive pull on cord.

OWNER’S MANUAL

INSTALLATION

Continued

CAUTION: Be careful of gas CAUTION: The wall switch must never be mounted directly above the fireplace where heat may damage it. If you relocate wall switch from lower fireplace cavity, it must be mounted either on side wall of mantel or on wall to side of fireplace.

For Recessed Installation

If fireplace is to be recessed into a wall (see Built-In Fireplace Installation, pages 17 and 18), we recommend mounting wall switch to left side of fireplace. The wall switch should be mounted approximately 12" from left edge of fireplace, and less than 60" from the floor. IMPORTANT: Do not locate wall switch directly in front of wall stud - there must be room behind wall board for wires from switch. If you choose to locate wall switch to right side of fireplace, the length of the cord restricts you to less than 6" from right edge of fireplace and less than 48" from floor.

Burner Outlet

Firebox

Tube

Bottom

Wire Tie

Gas Control

ValveSwitch with

Wall Plate

Figure 8 - Relocating Switch and Wall Plate

5.Carefully pass wall plate and cord through large elongated hole in rear of either left or right floor support bracket, depending on desired location of switch. Pass wall plate and cord through 1.5" diameter hole in side of fireplace outer casing (see Figure 9).

6.Pull wall plate and cord from fireplace making sure wall switch/plate assem- bly will reach desired mounting loca- tion without straining cord assembly.

lines and wiring when moving floor. CAUTION: Do not apply ex- cessive pull on cord.

10.Using a straight edge and pencil, con- nect the outer edges of the 4 holes for the rectangle (see Figure 10). This will give you cutting lines for the rectangle you will cut in the wall.

11.Using a keyhole saw, hack saw blade, drill, file, or other suitable tool, carefully cut out the rectangular opening. Note: The corners of the rectangle may be round. IMPORTANT: Do not exceed the size of the rectangle on template.

12.From inside the recessed opening for the fireplace, carefully pass switch/ plate assembly through the rectangu- lar opening to the outside of the wall.

13.Using wall anchors supplied in hard- ware package, fold wall anchor as shown in Figure11.

14.Insert wall anchor, wings first, into hole. Tap anchor flush to wall.

15.For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings. See Figure 14. IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick), do not pop open wings.

For Mantel Installation

If fireplace is to be installed into a mantel, (see Conventional Fireplace Installation, pages 16 and 17) the wall switch may be mounted on either side of the mantel, facing to the side. Do not locate wall switch any- where on the front face of the mantel.

CAUTION: Be careful of gas

Hole in

 

Outer

Hole in

Casing

 

Floor

 

Support

 

Bracket

Wall Switch/

Plate Assy

Make

Marks at

Centers

of Holes

Template from Manual

43/4"

3 3/4"

3/8"

3/8" Diameter

2 Holes

3/4"

3/16"

Cutting Lines

Tape

lines and wiring when moving floor.

1.Determine the new location for the wall switch. The wires attached to switch are six feet long.

2.Remove 2 screws securing plastic wall plate to bracket in fireplace lower cav- ity. Save screws.

3.Remove wire tie holding coiled wire attached to wall switch (see Figure 8).

4.Remove wall switch/plate assembly from bracket.

Figure 9 - Routing Wall Switch/Plate Through Fireplace for Relocation

Mounting Wall Switch to Wall for Re- cessed Fireplace

7.Create three openings on wall accord- ing to Template 1, page 35. This is best done by making a pattern to work with on your wall. Carefully cut page 35/36 from manual and tape paper template vertically onto wall at preferred location. Pierce the paper at the centers of the 2 holes with a nail or sharp pencil, leav- ing a mark on the wall. Do the same at centers of the four circles near the cor- ners of the rectangle.

8.Remove paper template from wall.

9.Drill 3/8" holes at each mark.

Figure 10 - Using Template for Wall Switch Installation