Desa CGEFP33NR Manual Lighting Instructions For Electrical, Power Outage, Operating Fireplace

Models: CGEFP33NR

1 38
Download 38 pages 52.94 Kb
Page 21
Image 21
MANUAL LIGHTING

OWNER’S MANUAL

OPERATING

FIREPLACE

Continued

4.To lower flame, push HI/LO button on wall switch once.

Note: This fireplace does not have a pilot-only mode.

POWER OUTAGE CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

3. Point remote control toward the

lower front of fireplace and push

both buttons at the same time. Hold

for 6 seconds. The gas valve will open

and electronic ignition will begin

sparking to light the pilot. Note: You

will be able to hear a clicking sound

during this process. LED on wall

switch will light.

Note: You may be running this

heater for the first time after connect-

ing to gas supply or at the start of

your heating season. If so, the ON

button may need to be pressed again.

MANUAL LIGHTING

INSTRUCTIONS

FOR ELECTRICAL

POWER OUTAGE

TO TURN OFF GAS WARNING: You must operate this heater with the fireplace screen in place. Make sure fire- place screen is in place before running heater.

Manual

Pilot Ignitor

Burner Electrode

Figure 49 - Pilot

Automatic Ignitor Electrode

This will allow air to bleed from gas

system. If several attempts to light

pilot fail, contact a qualified service

person or gas supplier for repairs.

Until repairs are made, light and op-

erate manually (see Manual Lighting

Instructions for Electrical Power Out-

age, pages 20 and 21).

4. When pilot flame is lit, the thermo-

couple is heated by the flame. When

thermocouple becomes hot (5 to 15

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Open damper or window to vent smell. This will only last a few hours.

Because this fireplace has an electronic ignition system, in the event there is a loss of power, it will be necessary to manually light the pilot with the piezo ignitor. After the pilot is lit, the main burner will light

Manual Ignition Bypass Switch (Up is for Remote Control)

 

MANUAL

ON/OFF

 

Button

 

IGNITION

 

 

 

HI LO

ON OFF

HI/LO

LED

Wall

Switch

Button

 

 

Figure 50 - Control Locations

B.Using Hand-Held Wireless Remote Control

1.Set manual ignition bypass switch on control panel to OFF position (auto- matic ignition position).

2.Wait five (5) minutes to clear out any gas. Smell for gas around heater and near floor. If you smell gas, STOP! Follow “B” in the safety information on warnings plate. If you don’t smell gas, go to the next step.

seconds), main burner will automati-

cally light on high flame.

5. To lower flame, point remote control

toward lower front of fireplace and

push HI/LO button once.

Note: This fireplace does not have a

pilot-only mode.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater - Wall Switch

Push ON/OFF button on wall switch once.

Shutting Off Heater - Wireless Remote Control

Point remote control toward lower front of fireplace and push both buttons at the same time.

automatically.

1.Follow steps 1 through 3 under Nor- mal Lighting Instructions, page 20.

2.Set manual ignition bypass switch on control panel to ON position (manual ignition position). See Figure 51.

3.The pilot is attached to the rear of the front burner. You will be able to see the pilot and spark electrode without removing the screen or logs.

4.Place the magnetic manual override handle, provided with this unit, on the end of the gas valve stem (see Fig- ure 51).

Gas

Piezo

 

Manual Ignition

 

Bypass Switch

Valve

Ignitor

 

(Down is ON)

HI/LO

 

 

IGNITION

 

 

 

 

MANUAL

 

Button

 

 

 

 

 

 

HI LO

ON OFF

Magnetic

 

 

 

 

Manual Override

LED

LED

Handle

Wall

 

ON/OFF

 

 

 

 

 

Switch

Button

 

Figure 51 - Control Locations

Continued

107569

21

For more information, visit www.desatech.com

Page 21
Image 21
Desa CGEFP33NR Manual Lighting Instructions For Electrical, Power Outage, To Turn Off Gas To Appliance, Continued