OWNER’S MANUAL
OPERATING
FIREPLACE
Continued
4.To lower flame, push HI/LO button on wall switch once.
Note: This fireplace does not have a
CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.
3. Point remote control toward the |
lower front of fireplace and push |
both buttons at the same time. Hold |
for 6 seconds. The gas valve will open |
and electronic ignition will begin |
sparking to light the pilot. Note: You |
will be able to hear a clicking sound |
during this process. LED on wall |
switch will light. |
Note: You may be running this |
heater for the first time after connect- |
ing to gas supply or at the start of |
your heating season. If so, the ON |
button may need to be pressed again. |
MANUAL LIGHTING
INSTRUCTIONS
FOR ELECTRICAL
POWER OUTAGE
WARNING: You must operate this heater with the fireplace screen in place. Make sure fire- place screen is in place before running heater.
Manual
Pilot Ignitor
Burner Electrode
Figure 49 - Pilot
Automatic Ignitor Electrode
This will allow air to bleed from gas |
system. If several attempts to light |
pilot fail, contact a qualified service |
person or gas supplier for repairs. |
Until repairs are made, light and op- |
erate manually (see Manual Lighting |
Instructions for Electrical Power Out- |
age, pages 20 and 21). |
4. When pilot flame is lit, the thermo- |
couple is heated by the flame. When |
thermocouple becomes hot (5 to 15 |
NOTICE: During initial operation of new heater, burning logs will give off a
Because this fireplace has an electronic ignition system, in the event there is a loss of power, it will be necessary to manually light the pilot with the piezo ignitor. After the pilot is lit, the main burner will light
Manual Ignition Bypass Switch (Up is for Remote Control)
| MANUAL | ON/OFF |
| Button | |
| IGNITION | |
|
| |
| HI LO | ON OFF |
HI/LO | LED | Wall |
Switch | ||
Button |
|
|
Figure 50 - Control Locations
B.Using
1.Set manual ignition bypass switch on control panel to OFF position (auto- matic ignition position).
2.Wait five (5) minutes to clear out any gas. Smell for gas around heater and near floor. If you smell gas, STOP! Follow “B” in the safety information on warnings plate. If you don’t smell gas, go to the next step.
seconds), main burner will automati- |
cally light on high flame. |
5. To lower flame, point remote control |
toward lower front of fireplace and |
push HI/LO button once. |
Note: This fireplace does not have a |
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater - Wall Switch
Push ON/OFF button on wall switch once.
Shutting Off Heater - Wireless Remote Control
Point remote control toward lower front of fireplace and push both buttons at the same time.
automatically.
1.Follow steps 1 through 3 under Nor- mal Lighting Instructions, page 20.
2.Set manual ignition bypass switch on control panel to ON position (manual ignition position). See Figure 51.
3.The pilot is attached to the rear of the front burner. You will be able to see the pilot and spark electrode without removing the screen or logs.
4.Place the magnetic manual override handle, provided with this unit, on the end of the gas valve stem (see Fig- ure 51).
Gas | Piezo |
| Manual Ignition | ||
| Bypass Switch | ||||
Valve | Ignitor |
| (Down is ON) | ||
HI/LO |
|
| IGNITION |
| |
|
|
| MANUAL |
| |
Button |
|
|
| ||
|
|
| HI LO | ON OFF | |
Magnetic |
|
|
|
| |
Manual Override | LED | LED | |||
Handle | Wall | ||||
| ON/OFF |
| |||
|
|
| |||
| Switch | Button |
|
Figure 51 - Control Locations
Continued
107569 | 21 | For more information, visit www.desatech.com |