Desa CGF280PT, CGF265PVA Inspecting Burners, Pilot Flame Pattern, Front Burner Flame Pattern

Models: CGF265PVA CGF280PT

1 40
Download 40 pages 8.73 Kb
Page 26
Image 26
INSPECTING BURNERS

INSPECTING BURNERS

26

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 30 shows a correct pilot flame pattern. Figure 31 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the fireplace will shut down.

Thermocouple

Pilot Burner

Thermocouple

Pilot Burner

 

 

Figure 30 - Correct Pilot

Figure 31 - Incorrect Pilot

Flame Pattern

Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 31

turn fireplace off (see To Turn Off Gas to Appliance, page 23 [Thermostat- controlled models} or page 25 [Manually-controlled models])

see Troubleshooting, pages 27 through 30

FRONT BURNER FLAME PATTERN

Figure 32 shows correct front burner flame pattern. Figure 33 shows incorrect front burner flame pattern. The incorrect burner flame pattern shows yellow tipping at top of blue flame.

WARNING

WARNING ICON

G 001

If front burner flame pattern shows yellow tipping, your fireplace could produce increased levels of carbon monoxide. Follow instruc- tions at bottom of this page. Yellow flame on rear burner is normal.

NOTICE

Do not mistake orange flames with yellow tipping. Dirt or other fine particles are burned by fireplace, causing brief patches of orange flame.

CORRECT FLAME PATTERN AT HIGH POSITION

Figure 32 - Correct Front Burner Flame Pattern

Yellow

Tipping

At Top

of Blue

Flame

INCORRECT FLAME PATTERN AT HIGH POSITION

Figure 33 - Incorrect Front Burner Flame Pattern

If front burner flame pattern is incorrect, as shown in Figure 33

turn fireplace off (see To Turn Off Gas to Appliance, page 23 [Thermostat- controlled models} or page 25 [Manually-controlled models])

see Troubleshooting, pages 27 through 30

102665

Page 26
Image 26
Desa CGF280PT, CGF265PVA installation manual Inspecting Burners, Pilot Flame Pattern, Front Burner Flame Pattern