AIR FOR COMBUSTION

AND VENTILATION

Continued

Ventilation

 

Grills

Or

into Adjoining

Remove

Room,

Door into

Option 1

Adjoining

 

Room,

 

Option 3

12"

Ventilation Grills

Into Adjoining Room,

Option 2

12"

Figure 2 - Ventilation Air from Inside Building

Ventilation Air From Outdoors

 

Provide extra fresh air by using ventilation

 

grills or ducts. You must provide two per-

 

manent openings: one within 12" of the

 

ceiling and one within 12" of the floor.

Outlet

Connect these items directly to the outdoors

Air

or spaces open to the outdoors. These spaces

 

include attics and crawl spaces. Follow the

 

National Fuel Gas Code NFPA 54/ANSI

 

Z223.1, Section 5.3, Air for Combustion and

 

Ventilation for required size of ventilation

 

grills or ducts.

Inlet

IMPORTANT: Do not provide openings

Air

for inlet or outlet air into attic if attic has a

 

thermostat-controlled power vent. Heated

 

air entering the attic will activate the power

 

vent.

 

Ventilated

Outlet Attic

Air

To Attic

To

Crawl

Space

Inlet Air

 

Ventilated

 

 

Crawl Space

 

 

Figure 3 - Ventilation Air from Outdoors