INSTALLING GAS PIPING TO FIREPLACE LOCATION

NOTICE: A qualified service per- son must connect fireplace to gas supply. Follow all local codes.

CAUTION: For propane/LP units, never connect heater di- rectly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane/LP supply.

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

manual shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

approved flexible gas line with gas con- nector (if allowed by local codes) (not provided)

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the A.G.A. design-certified manual shutoff valve from your retailer.

For propane/LP connection only, the in- staller must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to fireplace. If pipe is too small, undue loss of pressure will occur.

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 35).

Propane/LP

Supply Tank

External

Regulator

Vent

Pointing

Down

Figure 34 - External Regulator with Vent Pointing Down (Propane/LP Only)

A.G.A. Design-Certified Manual Shutoff Valve with 1/8" NPT Tap*

Approved Flexible

Gas Line

3" Minimum

Check your building codes for any special requirements for locating manual shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap/drip leg in supply line as shown in Figure 35. Locate sediment trap/drip leg where it is within reach for cleaning. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and con- taminants. This keeps them from going into fireplace gas controls. If sediment trap/drip leg is not installed or is installed wrong, fireplace may not run properly.

Natural - From Gas

Meter (5" W.C. to 10.5"

W.C. Pressure )

Propane/LP - From External

Regulator (11" W.C. to 14"

W.C. Pressure)

occur. Install external regulator with the vent pointing down as shown in Figure 34. Pointing the vent down protects it from freezing rain or sleet.

Cap Pipe Nipple Tee Joint

Sediment Trap/Drip Leg

Figure 35 - Gas Connection

*The A.G.A. design-certified manual shutoff valve may be supplied with the appliance or you can purchase it from your retailer.

18

105456

Page 18
Image 18
Desa CHDV34(N/P)(A) installation manual Installing GAS Piping to Fireplace Location, Installation Items Needed

CHDV34(N/P)(A) specifications

Desa CHDV34(N/P)(A) is a state-of-the-art heating solution designed to address the modern needs of both residential and commercial spaces. This system is distinguished by its innovative design, efficiency, and reliability, making it a top choice for users seeking an effective climate control solution.

One of its main features is the advanced heat exchange technology employed in the unit. The system utilizes a high-efficiency heat exchanger to increase thermal efficiency, ensuring that a minimal amount of energy is wasted during the heating process. This feature not only helps reduce energy consumption but also contributes to lower utility bills over time, making it an environmentally friendly choice.

Another significant characteristic of the Desa CHDV34(N/P)(A) is its versatility in installation. The unit can be installed in various locations, including ceilings, walls, or floors, affording users the flexibility to optimize space usage. This adaptability makes it suitable for a wide range of applications, from small homes to larger commercial settings, tailoring to the unique requirements of each space.

Technologically, the Desa CHDV34(N/P)(A) is equipped with smart features that enhance its usability. It includes programmable thermostats and remote control capabilities that allow users to adjust settings conveniently from a distance. This feature not only adds comfort but also ensures that the heating system operates efficiently, reducing heating costs while maintaining a pleasant indoor environment.

Additionally, the Desa CHDV34(N/P)(A) is designed with safety in mind. It incorporates multiple safety features, including overheat protection and automatic shut-off systems, ensuring secure operation even under prolonged usage. This commitment to safety contributes to user peace of mind, knowing that they are using a reliable heating solution.

In conclusion, Desa CHDV34(N/P)(A) stands out for its efficiency, versatility, and technological advancements. It is an ideal choice for users looking to enhance their comfort while minimizing environmental impact and operational costs. With its innovative features and robust safety measures, it encapsulates what modern heating solutions should offer, positioning itself as a frontrunner in the market.