MANUAL LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas con- trol which has been under water.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information in column one.

2.Open lower louver panel.

3.Disconnect the wire that runs from TH to TPTH from the control valve.

4.Turn off all electric power to the fireplace.

5.Push in gas control knob slightly and

turn clockwise Manual background to “OFF”.

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation in column one. If you don't smell gas, go to the next step.

7.The pilot is located by the main burner and should not require ac- cessing for lighting.

8.Turn knob on gas control counter-

clockwise Manual background to “PILOT”.

9.Push in control knob all the way and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold for about one (1) minute after the pilot is lit. Release knob and it will pop back. Pilot should remain lit. If it goes out, re- peat steps 5 through 8.

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after sev- eral tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.

Gas Control Knob

Variable Control Knob

Piezo

 

Ignitor

IH

ILOT

P

O

F

N

F

 

O

 

 

LO

Figure 53 - Control Valve

10.Reconnect the wire that runs from TH to TPTH to the control valve.

11.Turn on all electric power to the fireplace.

12.Turn gas control counterclockwise Manual background to “ON”.

13.This valve is equipped with a HI/LO feature. Set fireplace input as desired.

14.Close lower louver panel.

TO TURN OFF GAS

TO APPLIANCE

1.Open lower louver panel.

2a. Set selector switch in the OFF position.

2b. Turn ON/OFF REMOTE switch to OFF.

2c. Disconnect wire that runs from TH to TPTH.

3.Turn off all electrical power to the appliance if service is to be performed.

4.Push in gas control knob slightly and

turn clockwise Manual background to “OFF”.

5.Set selector switch in the OFF position to prevent draining the battery.

6.Close lower louver panel.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

1.Turn control knob clockwise Manual background to the PILOT position.

2.Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Remove glass door (see Removing/ Replacing Glass Door, page 21).

2.Follow steps 1 through 8 under Light- ing Instructions, page 14.

3.Depress control knob and light pilot with match.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Follow steps 10 through 14.