CLEANING AND

INSPECTING BURNERS

Continued

FRONT BURNER FLAME PATTERN

Manual background WARNING: If front burner flame pattern shows yellow tip- ping, your fireplace could pro- duce increased levels of carbon monoxide. Follow instructions below. Yellow flame on rear burner is normal.

NOTICE: Do not mistake orange flames with yellow tipping. Dirt or other fine particles are burned by fireplace, causing brief patches of orange flame.

Figure 40 shows correct front burner flame pat- tern. Figure 41 shows incorrect front burner flame pattern. The incorrect burner flame pattern shows yellow tipping at top of blue flame.

If front burner flame pattern is incorrect, as shown in Figure 41

turn heater off (see To Turn Off Gas to Appli- ance, page 20)

see Troubleshooting, page 25

Figure 40 - Correct Burner Flame Pattern

Yellow Tipping At

Top of Blue Flame Manual background

Figure 41 - Incorrect Burner Flame

Pattern

CLEANING AND

MAINTENANCE

Manual background WARNING: Turn off fireplace

and let cool before cleaning.

Manual background CAUTION: You must keep control areas, burner and cir- culating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

Manual background WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.

BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the directions on the can. If you donʼt follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.