Desa EVGL850N installation manual Service Hints, Technical Service, Wiring Diagram

Models: EVGL850N

1 20
Download 20 pages 3.06 Kb
Page 14
Image 14

® EVGL850N

VENTED TYPE DECORATIVE APPLIANCE

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burner will have delayed ignition

fireplace will not produce specified heat

propane/LP gas supply may be low

When Gas Quality Is Bad

pilot will not stay lit

burner will produce flames and soot

fireplace will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP gas supplier.

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni- cal Service Department at 1-800-323-5190.

You can also visit DESA International’s technical services web site at www.desatech.com.

WIRING DIAGRAM

Ignitor Pilot

INCOMING

MAIN GAS

SUPPLY

Control

Hearth Pan

 

 

 

Valve

IGN

 

 

 

 

 

 

HEAT

MODEL

 

 

LIMIT

 

 

SWITCH

SP745 IGNITIONCONTROL

Robertshaw

 

PV GND TRTHPV/MV

 

EV1

 

 

 

MV

 

 

 

EV2

 

 

 

24V AC

 

 

STEP DOWN

TRANSFORMER

120V AC

GAS LINE

TO

BURNER

WALL SWITCH (SUPPLIED)

ON

OFF

BLACK

WHITE GREEN

OPTIONAL

REMOTE

CONTROL

Connectors (Not Supplied)

Field Wire

BLACK

INCOMING

 

WHITE

120V AC

GREEN

(FUSE BOX

OR BREAKER)

 

ELECTRICAL RATING:

120v, 60Hz, 0.7A

14

107050

Page 14
Image 14