Desa FB32C installation manual Installing, BUILT-IN Firebox Installation

Models: FB32C

1 28
Download 28 pages 17.46 Kb
Page 17
Image 17

INSTALLING

10.

If installing GA3500A blower (FB32C firebox only), route blower electrical

 

cord through bushing in right side firebox support and bushing in side access

 

 

Continued

 

opening of firebox. Plug electrical cord into electrical outlet. See Installing

 

 

Blower Accessory, page 12.

 

11.

Carefully insert firebox into cabinet mantel. Be careful not to scratch or damage

 

 

hearth base, cabinet mantel, or any laminate trim on hearth base. Remove

 

 

protective material from top of hearth base and from front of firebox (if any).

 

12.

If using optional GA6090 brass trim kit, install the trim after final finishing

 

 

and/or painting of wall. See instructions included with brass trim accessory for

 

 

attaching brass trim.

 

13.

Check all gas connections for leaks. See Checking Gas Connections in log set

 

 

owner's manual.

Figure 17 - Inserting Firebox Into Cabinet Mantel

BUILT-IN FIREBOX INSTALLATION

Built-in installation of this firebox involves installing firebox into a framed-in enclosure. This makes the front of firebox flush with wall. If installing a mantel above the firebox, but you must follow the clearances shown in Figure 7, page 11. Follow the instructions below to install the firebox in this manner.

 

Height

Front Width

Depth

 

 

 

 

 

 

 

 

Model #

Actual

Framing

Actual

Framing

Actual

Framing

 

 

 

 

 

 

 

 

FB32C

32 3/8"

33"

34 5/16"

35 1/2"

16 11/16"

17

3/4"

FB32NC

33 11/16"

34 1/4"

34 5/16"

35 1/2"

16 11/16"

17

3/4"

1.Frame in rough opening. Use dimensions shown in Figure 18 for the rough opening.

17 3/4"

33" (FB32C)

34 1/4" (FB32NC)

35 1/2"

 

Figure 18 - Rough Opening for Installing in Wall

Continued 17

 

103296

Page 17
Image 17
Desa FB32C installation manual Installing, BUILT-IN Firebox Installation