Desa VYGF33NRC, FPVF33PRA Wiring Diagram, Specifications, Replacement Parts, Technical Service

Models: FPVF33PRA VYGF33NRC

1 40
Download 40 pages 24.01 Kb
Page 29
Image 29
Wiring Diagram

Wiring Diagram

Note: For proper operation of optional accessories, the wires from the switch to the control must be connected exactly as shown.

AUTOSpecifications

OFF

ON

Thermopile

Specifications

VYGF33NRC and FPVF33NRA

• Rating: 20,000/30,000

• Gas Type: Natural Gas

• Ignition: Piezo

• Pressure Manifold: 3.5" W.C.

• Inlet Gas Pressure (in. of water): Maximum - 10.5", Minimum* - 5"

• Shipping Weight: 122 lbs.

VYGF33PRC and FPVF33PRA

• Rating: 20,000/33,000

• Gas Type: Propane/LP Gas

• Ignition: Piezo

• Pressure Manifold: 8.0" W.C.

• Inlet Gas Pressure (in. of water): Maximum - 14", Minimum* - 11"

• Shipping Weight: 122 lbs. * For input adjustment

Replacement Parts

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

Parts Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling DESA Heating Products, have ready

your name and address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products at 1-866-672-6040 for referral information. When calling DESA Heating Products, have ready

model number of your fireplace

the replacement part number

Technical Service

You may have further questions about installation, operation or troubleshooting. If so, contact DESA Heating Products’Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.

You can also visit DESA Heating Products’techni- cal services web site at www.desatech.com.

Service Hints

When Gas Pressure Is Too Low

• pilot will not stay lit

• burner will have delayed ignition

• fireplace will not produce specified heat

• for propane/LP unit, propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local gas supplier.