Desa VYGF33NRC, FPVF33PRA Troubleshooting, Observed Problem, Possible Cause, Remedy

Models: FPVF33PRA VYGF33NRC

1 40
Download 40 pages 24.01 Kb
Page 25
Image 25
Troubleshooting

Troubleshooting

OBSERVED PROBLEM WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

POSSIBLE CAUSE CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

When ignitor button is pressed,

1. Ignitor electrode not con-

1.

Reconnect ignitor cable

there is no spark at ODS/pilot

2.

nected to ignitor cable

2.

Free ignitor cable if pinched

 

Ignitor cable pinched or wet

 

 

 

 

by any metal or tubing. Keep

 

3.

Piezo ignitor nut is loose

3.

ignitor cable dry

 

Tighten nut holding piezo ig-

 

 

 

 

nitor to base panel of log set. Nut

 

4.

Broken ignitor cable

4.

is located behind base panel

 

Replace ignitor cable

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

6.

Ignitor electrode positioned

6.

Replace pilot assembly

 

7.

wrong

7.

Replace pilot assembly

 

Ignitor electrode broken

 

 

 

 

 

When ignitor button is pressed,

1. Gas supply turned off or equip-

1.

Turn on gas supply or open

there is spark at ODS/pilot but

 

ment shutoff valve closed

2.

equipment shutoff valve

no ignition

2. Control knob not in PILOT

Turn control knob to PILOT

 

3.

position

3.

position

 

Control knob not pressed in

Press in control knob while in

 

4.

while in PILOT position

4.

PILOT position

 

Air in gas lines when in-

Continue holding down con-

 

 

stalled

 

trol knob. Repeat igniting op-

 

5.

Depleted gas supply (pro-

5.

eration until air is removed

 

Contact local propane/LP gas

 

6.

pane/LP only)

6.

company

 

ODS/pilot is clogged

Clean ODS/pilot (see Clean-

 

 

 

 

ing and Maintenance, page

 

 

 

 

24) or replace ODS/pilot as-

 

7.

Gas regulator setting is not

7.

sembly

 

Replace gas regulator

 

 

correct

 

 

 

113109-01C

www.desatech.com

25

Page 25
Image 25
Desa VYGF33NRC, FPVF33PRA installation manual Troubleshooting, Observed Problem, Possible Cause, Remedy