Desa VYGF33NRC, FPVF33PRA installation manual Continued, Installation Clearances

Models: FPVF33PRA VYGF33NRC

1 40
Download 40 pages 24.01 Kb
Page 9
Image 9
INSTALLATION CLEARANCES

Installation

Continued

Assembling and attaching OPTIONAL perimeter trim (Included with Mantel Accessory)

IMPORTANT: If you are recessing the firebox in a wall, do not attach perimeter trim at this time. See Built-In Fireplace Installation, page 11.

Note: The instructions below show assembling and attaching perimeter trim to fireplace.

1.Remove packaging from three pieces of pe- rimeter trim.

2.Locate four perimeter screws, two adjusting plates with set screws and two shims in the hardware packet.

3.Align shim under adjusting plate as shown in

Figure 6.

4.Slide one end of adjusting plate/shim in slot on mitered edge of top perimeter trim (see Figure 6).

5.Slide other end of adjusting plate/shim in slot on mitered edge of side perimeter trim (see Figure 6).

6.While firmly holding edges of perimeter trim together, tighten both set screws on the adjust- ing plate with slotted screwdriver.

7.Repeat steps 1 through 6 for other side.

8.Tighten trim hanging screws (#10 x 6.25 shoulder) into holes in cabinets. Place the assembled trim onto fireplace cabinet. Align hanging notches on trim with hanging screws on side of fireplace (see Figure 7). Push trim firmly into place, sliding hanging notches over hanging screws.

Set Screws

 

Adjusting

Top

Side Trim

Plate

Trim

 

Shim

 

 

Mitered

Slot

Slot

Edge

 

 

Figure 6 - Assembling Perimeter Trim

Trim

Manual backgroundHanging

Screws

Hanging

Notches

Manual background on Trim

Assembled Manual background

Trim

Figure 7 - Attaching Perimeter Trim to

Fireplace

INSTALLATION CLEARANCES

Manual background WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling and adjoining wall.

Carefully follow the instructions below. This will ensure safe installation.

Minimum Clearances For Side Combustible

Material, Side Wall and Ceiling

A. Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 8.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combus- tible material must be 4" from the side of the fireplace opening (see Figure 8).

B. Clearances from the top of the fireplace opening to the ceiling should not be less than 42".

Minimum Clearance to Combustible Materials

Top: 42", Left and Right Sides: 16"

Bottom and Rear: 0"

Example

*

*Minimum 16" from Side Wall

Figure 8 - Minimum Clearance for

Combustible to Wall

113109-01Cwww.desatech.com

Page 9
Image 9
Desa VYGF33NRC, FPVF33PRA installation manual Continued, Installation Clearances