 WARNING: Never install the heater

INSTALLATION

Continued

LOCATING HEATER

This heater is designed to be mounted on a wall.

Manual background WARNING: Maintain the minimum clearances shown in Figure 4. If you can, provide greater clearances from floor, ceiling and joining wall.

Manual background WARNING: Never install the heater

in a bathroom (10,000 Btu/hr only. 6,000 Btu/hr models are allowed in a bathroom. Check local codes.)

in a recreational vehicle

where curtains, furniture, clothing or other flammable objects are less than 36" (91.5 cm) from the front, top or sides of the heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

 

CEILING

6"

36" (91.5 cm)

Minimum

(15.3 cm)

Minimum

 

From

 

Sides Of

 

Heater

 

 

Right

Left

Side

Side

 

3" (7.7 cm)

Minimum To Top Surface

Of Carpeting, Tile Or Other

Combustible Material

Figure 4 - Mounting Clearances As

Viewed From Front of Heater

Manual background CAUTION: If you install the heater in a home garage

heater pilot and burner must be at least 18" (45.7 cm) above floor

locate heater where moving vehicle will not hit it

Manual background CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning flu- ids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 5. If high hu- midity is experienced, a dehumidifier may be used to help lower the water vapor content in the air.

For convenience and efficiency, install heater

where there is easy access for operation, inspec- tion and service

in coldest part of room

THERMOSTAT SENSING BULB (Thermostat Models Only)

The thermostat sensing bulb is located inside the heater. Do not move this bulb during installation or operation of the heater.

INSTALLING HEATER TO WALL

Marking Screw Locations

1. Determine where you will locate heater.

Manual background WARNING: Maintain mini- mumclearancesshowninFigure 5, page 9. If you can, provide greater clearances from floor and joining wall.

2.Mark two mounting screw locations on wall (see Figure 5, page 9).

8