Desa GWP10 GWN10T Continued, Lighting Instructions, create a possible health hazard, Control

Models: GWP10 GWN10T

1 28
Download 28 pages 34.26 Kb
Page 13
Image 13
LIGHTING

OPERATING HEATER

Continued

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information, page 12.

2.Make sure equipment shutoff valve is fully open.

3.Turn off any electric power to the appliance if service is to be performed.

4.Turn control knob clockwise create a possible health hazard to the OFF position.

5.Wait five minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, page 12. If you donʼt smell gas, go to the next step.

6.Thermostat Models: Turn control knob

counterclockwise room. Read owner’s manual for to the PILOT position. Press in control knob for five (5) seconds.

Manual Models: Press in and turn control

knob counterclockwise Ignitor Button to the PILOT position. Keep control knob pressed in for five (5) seconds.

7.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. Note: You may be running this heater for the first time after hooking up to gas supply. If so, you may need to press in control knob for 30 seconds or more. This will allow air to bleed from the gas system. If needed, keep pressing ignitor button until pilot lights. If ignitor does not light pilot, refer to Troubleshooting, page 16 or contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 14.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 thru 7. Thermostat models have a safety interlock system. Wait one (1) minute before lighting pilot again.

9.Turn control knob counterclockwise Control to desired heating level. The main burner should light. Manual control heaters should be used in locked positions.

WARNING: Always operate

manual control heaters at the

locked positions. Operation

between these positions may

create a possible health hazard

if used in a poorly ventilated

room. Read owner’s manual for

complete instructions.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

Ignitor Button

Control

Knob

 

Figure 17 - Control Knob In The OFF Position for Manual Control Models

Ignitor

Control

Button

Knob

 

 

F

 

F

 

O

Figure 18 - Control Knob In The OFF

Position for Thermostat Models

Thermocouple

Ignitor Electrode

Pilot

 

 

Burner

Figure 19 - Pilot

TO TURN OFF GAS TO APPLIANCE Shutting Off Heater

1.Turn control knob clockwise Knob to the OFF position.

2.Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise

to the

PILOT position.

 

117001-01A

www.desatech.com

13

Page 13
Image 13
Desa GWP10 GWN10T Continued, Lighting Instructions, create a possible health hazard, room. Read owner’s manual for, Knob