Heatiator NEVO4236I NEVO3630I owner manual •Remove the flue visor

Models: NEVO4236I NEVO3630I

1 75
Download 75 pages 43.98 Kb
Page 28
Image 28
•Remove the flue visor.

Install Top Vent Flue Baffle - No Elbow Configu- rations

Remove screws holding flue visor to firebox top. See Figure 7.7a.

Remove the flue visor.

Using the screws removed and the same holes, install the top vent flue baffle and flue visor.

-The flue baffle will be turned to install below the level of the firebox top for 12-30 ft vertical runs of vent. See Figure 7.7b.

-The flue baffle will be turned to install inside the flue for vertical vent runs of 31-60 ft. See Figure 7.7c.

Figure 7.7a Remove Flue Visor

Figure 7.7b 12 to 30 ft Vertical Run

Figure 7.7c 31 ft to 60 ft Vertical Run

28

Heatilator • Evolution • 4065-114 Rev. o • 11/11

Page 28
Image 28
Heatiator NEVO4236I NEVO3630I owner manual •Remove the flue visor