14 Finishing

14 Finishing

A. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as specified. Framing or finishing material closer than the minimums listed must be construct- ed entirely of non-combustible materials (i.e., steel studs, concrete board, etc).

Mantels

Note: All measurements in inches.

 

 

 

 

 

 

 

 

30 in. minimum

 

 

 

 

 

 

 

 

to ceiling

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

16

17

 

 

 

 

 

 

 

16

 

 

 

 

 

 

14

15

15-1/4

 

 

 

 

 

 

14-1/2

 

 

 

 

 

12

13

13-3/4

 

 

 

 

 

 

13

 

 

 

 

 

 

10

11

12-1/4

 

 

 

 

 

9

11-1/2

 

 

 

 

 

 

10-3/4

 

 

 

 

 

7

8

10

 

 

 

 

 

 

9-1/4

 

 

 

 

 

 

5

6

8-1/2

 

 

 

 

 

 

7-3/4

 

 

 

 

 

3

4

7

 

 

 

 

 

 

5-1/26-1/4

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

Measured from top of fireplace opening (in inches)

Figure 14.1 Minimum Vertical and Maximum Horizontal Dimensions

Mantel Legs or Wall Projections

Top of

Appliance

A. Mantel and Wall Projections Drywall

Note: All measurements in inches.Manual background AManual background

Manual background B Manual background

Manual background Mantel Leg or

Perpendicular Wall

A

B

1 in. (25 mm) min. to perpendicular wall

3-1/2 in. (89 mm) min. from fireplace opening to perpendicular wall

Figure 14.2 Mantel Leg or Wall Projections (Acceptable on both sides of opening)