6 Termination Locations

6 Termination Locations

A. Vent Termination Minimum Clearances

A. Vent Termination Minimum Clearances WARNING

Fire Risk.

Maintain vent clearance to combustibles as specified.

DO NOT pack air space with insulation or other materials.

Failure to keep insulation or other materials away from vent pipe may cause overheating and fire.

A

B

6 in. (minimum) up to 20 in.

18 in. minimum

152 mm/508 mm

457 mm

20 in. and over

0 in. minimum

Gas, Wood or Fuel Oil

Termination Cap

B

24 in. min.

(610 mm)

Termination

Cap

 

 

 

 

Horizontal

 

20 in.

 

 

overhang

 

 

 

 

 

 

 

 

 

 

(508 mm)

Vertical

Lowest

wall

Discharge

 

Opening

 

A *

Gas

Termination

Cap **

Storm Collar

 

 

12

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Roof

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flashing

 

 

 

 

 

Roof Pitch

 

 

 

 

 

 

 

 

 

 

 

 

 

is X / 12

 

 

 

 

H (min.) - Minimum height

 

 

 

 

from roof to lowest

 

 

 

 

 

discharge opening.

 

 

Roof Pitch

H (Min.) Ft.

 

Roof Pitch

H (Min.) Ft.

Flat to 6/12

 

1.0*

 

Over 11/12 to 12/12

4.0

Over 6/12 to 7/12

1.25*

 

Over 12/12 to 14/12

5.0

Over 7/12 to 8/12

1.5*

 

Over 14/12 to 16/12

6.0

Over 8/12 to 9/12

2.0*

 

Over 16/12 to 18/12

7.0

Over 9/12 to 10/12

2.5

 

Over 18/12 to 20/12

7.5

Over 10/12 to 11/12

3.25

 

Over 20/12 to 21/12

8.0

 

* 3 ft. minimum in snow regions

 

 

*If using decorative cap cover(s), this distance may need to be increased. Refer to the installation instructions supplied with the decorative cap cover.

**In a staggered installation with both gas and wood or fuel oil terminations, the wood or fuel oil termination cap must be higher than the gas termination cap.

Figure 6.2 Multiple Termination Caps

Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening

22