Mantel Clearances for Built- In Installation

INSTALLation

Continued

Mantel Clearances for Built- In Installation

If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.

NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual.

NOTICE: If your installation does not meet the minimum clear- ances shown, you must do one of the following:

raise the mantel to an accept- able height

remove the mantel

 

 

Mantel Shelf

 

 

 

 

 

 

Note: All vertical

10"

 

 

 

 

measurements are

8"

 

 

 

 

from top of fireplace

 

 

 

 

opening to bottom

6"

 

 

 

 

 

 

 

 

of mantel shelf. All

2 1/2"

 

 

 

 

 

 

 

 

measurements are

 

 

 

 

 

in inches.

 

 

 

 

 

Side of

 

 

 

 

 

Firebox

13"

16"

19"

21"

 

 

 

 

 

 

 

 

 

Figure 11 - Minimum Mantel Clearances

for Built-In Installation

OPTIONAL MANTEL Installation

Refer to instructions provided with the mantel for assembly and installation instructions. Refer to instructions on page 4 for firebox assembly. If a blower accessory is being used, it should be in- stalled before securing your fireplace to the mantel (see Installing Blower Accessory GA3450TA).

installing blower accessory GA3450TA

Removing Upper Louver Assembly

To install the blower accessory, you must first remove the upper louver assembly.

1.Lift screen off heater.

2.Remove 4 screws from louver assembly (see Figure 12). Save these screws.

3.Pull louver assembly straight out from the cabinet. Be careful not to scratch the paint. Set louver assembly and screws aside.

Blower Bracket

Mounting Holes

 

Upper

Screws

Louver

Assembly

 

Figure 12 - Removing Upper Louver

Assembly

Removing Valve Cover Shield

1. Open bottom louver assembly by swinging the assembly down (see Figure 13, page 13).

2. Using short Phillips screwdriver, remove the screw under the center of the branch support. Rotate valve cover shield clockwise and slide out. IMPORTANT: Do not remove shoulder screw on the left side of valve cover shield. Slide the valve cover shield off of the shoulder screw (see Figure 13, page 13).

Note: If you do not have a short Phillips screwdriver, the screen, log set and branch support must be removed so a longer screw- driver may be used. See Connecting Equip- ment Shutoff Valve to Heater Control, page 16, steps 1 and 2.