Desa CGCFTP, CGCFTN installation manual Operating Fireplace, For Your Safety Read Before Lighting

Models: CGCFTP, CGCFTN HDCFTP, HDCFTN, CGCFTP, CGCFTN

1 32
Download 32 pages 44.68 Kb
Page 18
Image 18
Operating Fireplace

Operating Fireplace

FOR YOUR SAFETY

READ BEFORE LIGHTING

FOR YOUR SAFETY WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

LIGHTING WARNING:You must operate this fireplace with the fireplace screen in place. Make sure fire- place screen is installed before running fireplace.

NOTICE: During initial operation of new fireplace, burning logs will give off a paper-burning smell. Orange flame will also be present. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.

1.STOP! Read the safety information in column 1.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clockwise Manual background to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the safety information, column 1. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise Manual background to the PILOT position. Press in control knob for five (5) seconds (see Figure 25).

Note: You may be running this fireplace for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

Ignitor

Control

Knob

Button

 

Figure 25 - Control Knob In The OFF

Position

18

www.desatech.com

111044-01J

Page 18
Image 18
Desa CGCFTP, CGCFTN installation manual Operating Fireplace, For Your Safety Read Before Lighting, Lighting Instructions