TROUBLESHOOTING
Continued
WARNING: If you smell gas
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | |||
|
|
|
|
|
|
Fireplace produces unwanted | 1. | Fireplace burning vapors from | 1. | Ventilate room. Stop using | |
odors |
| paint, hair spray, glues, etc. |
| odor causing products while | |
|
| (see IMPORTANT statement |
| fireplace is running | |
| 2. | above) | 2. | Refill supply tank | |
| Low fuel supply | ||||
| 3. | Gas leak. See Warning | 3. | Locate and correct all leaks | |
|
| statement at top of page |
| (see Checking Gas Connec- | |
|
|
|
| tions, page 16) | |
|
|
|
|
|
|
Fireplace shuts off in use (ODS | 1. | Not enough fresh air is avail- | 1. | Open window and/or door for | |
operates) | 2. | able | 2. | ventilation | |
| Low line pressure | Contact local propane/LP or | |||
| 3. | O D S / p i l o t i s p a r t i a l l y | 3. | natural gas company | |
| Clean ODS/pilot (see Cleaning | ||||
|
| clogged |
| and Maintenance, page 20) | |
|
|
|
|
|
|
Gas odor even when control knob | 1. | Gas leak. See Warning | 1. | Locate and correct all leaks | |
is in OFF position |
| statement at top of page |
| (see Checking Gas Connec- | |
| 2. | Control valve defective | 2. | tions, page 16) | |
| Replace control valve | ||||
|
|
|
|
|
|
Gas odor during combustion | 1. | Foreign matter between con- | 1. | Take apart gas tubing and | |
| 2. | trol valve and burner | 2. | remove foreign matter | |
| Gas leak. See Warning | Locate and correct all leaks | |||
|
| statement at top of page |
| (see Checking Gas Connec- | |
|
|
|
| tions, page 16) | |
|
|
|
|
|
|
Moisture/condensation noticed | 1. | Not enough combustion/ven- | 1. | Refer to Air for Combustion | |
on windows |
| tilation air |
| and Ventilation requirements | |
|
|
|
| (page 6) |
www.desatech.com | 25 |