TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

Yellow flame during burner

1.

Not enough air

1.

Check burner for dirt and

combustion

 

 

 

debris. If found, clean burner

 

 

 

 

(see Cleaning and Mainte-

 

2.

Gas regulator defective

2.

nance, page 20)

 

Replace gas regulator

 

 

 

 

 

 

Slight smoke or odor during initial

1.

Residues from manufacturing

1.

Problem will stop after a few

operation

 

processes

 

hours of operation

 

 

 

 

 

 

Fireplace produces a whistling

1.

Turning control knob to HI

1.

Turn control knob to LO

noise when burner is lit

 

position when burner is cold

 

position and let warm up for

 

2.

Air in gas line

2.

a minute

 

Operate burner until air is

 

 

 

 

removed from line. Have gas

 

 

 

 

line checked by local propane/

 

3.

Air passageways on fireplace

3.

LP gas company

 

Observe minimum installation

 

 

blocked

 

clearances (see Figures 6 and

 

4.

Dirty or partially clogged

4.

7, page 9)

 

Clean burner (see Cleaning

 

 

burner orifice

 

and Maintenance, page 20)

 

 

 

 

or replace burner orifice

 

 

 

 

 

 

White powder residue forming

1.

When heated, vapors from

1.

Turn heater off when using

within burner box or on adjacent

 

furniture polish, wax, carpet

 

furniture polish, wax, carpet

walls or furniture

 

cleaners, etc. may turn into

 

cleaners or similar products

 

 

white powder residue

 

 

 

Fireplace produces a clicking/

1.

Metal expanding while heating

1.

This is normal with most fire-

ticking noise just after burner is

 

or contracting while cooling

 

places. If noise is excessive,

lit or shut off

 

 

 

contact qualified service person

24

www.desatech.com

111044-01J

Page 24
Image 24
Desa HDCFTP, HDCFTN, CGCFTP, CGCFTN installation manual See Cleaning and Mainte, Maintenance