Operation

Continued

TO SELECT

HEATING LEVEL

WARNING: When running heater, set control knob at LOW, MED or HI locked positions. Never set control knob between locked positions. Poor combus- tion and higher levels of carbon monoxide may result.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Turn thermostat control knob counterclock-

wise to the desired heating level. The main burner should light. Set control knob to any heat level between 1 and 5 (see Figure 21).

Control Knob

Burners

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 21 - Burner Patterns

TO TURN OFF GAS

TO APPLIANCE

1.Turn control knob clockwise to the OFF position.

2.Turn off all electric power to the appliance if service is to be performed.

3.Close equipment shutoff valve (see Figure 16, page 13).

THERMOSTAT Control

OPERATION

The thermostatic control used on these models differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between 1 and 5. All plaques will turn off and on.

Note: The thermostat sensing bulb mea- sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation location, room size, open air temperatures, etc.) Frequent use of your heater will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 7, page 9).

2.Follow steps 1 through 7 under Lighting Instructions, page 14.

3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

4.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. Now follow step 9, under Lighting Instructions, page 14.

5.Replace front panel.

121255-01A

www.desatech.com

15

Page 15
Image 15
Desa LCR16PT, HDR18NT, LCR30NT, LCR26PT To Select Heating Level, To Turn OFF GAS To Appliance, Thermostat Control, Operation